  • Page 1 ENG/FR OPERATION AND INSTALLATION MANUAL Multi-fuel and SE models Guide d’utilisation et Mode d'Emploi Loxton 3 July 2016 revised June 2018...
  • Page 2: Health And Safety Precautions

    This manual refers to the stoves listed above, which are tested in accordance with EN 13240. Congratulations on your purchase of a new stove from Mendip Stoves. Please read this manual carefully to ensure that you get maximum enjoyment from your new stove and to prevent any problems. Please note that “all local regulations, including those referring to national and European Standards, need to be complied with when installing this appliance”.
  • Page 3: Important

    Older properties, especially, may have chimney faults or the cross section may be too large . Mendip Stoves recommend the use of a solid fuel flue lining system for all installations into existing chimneys. All chimney systems must be used in accordance with Building Regulations Approved Document J.
  • Page 4 If the stove has not been used for some time the flue should be checked for blockages before use. Do not modify the appliance; only use spares authorised by the manufacturer. STOVE DIMENSIONS AND CONNECTION MEASUREMENTS ...\loxton front and side 201 F Ped Loxton 3.2kW 525mm 380mm 320mm 125mm...
  • Page 5: Combustion Air

    Mendip stoves have been tested and are suitable to be installed on a 12mm non combustible plate such as 12 mm glass plates . Installation of all hearths should comply in size and construction so that it is in accordance with the provisions of the current Building Regulations Approved Document J.
  • Page 6: Connection To Chimney

    OPERATING YOUR STOVE - SUITABLE FUELS - LOXTON 3 The Mendip Loxton 3 model is tested to burn wood or smokeless coal. and wood briquettes . For a full list of suitable fuels, check with the official solid fuels approvals body, HETAS or Solid Fuel Association. Do not overload stove as this can cause excessive heat and damage the stove( see table on page 3).
  • Page 7 HOW TO LIGHT YOUR WOODBURNING STOVE 1. Place a few smaller pieces of dry wood (kindling) in the stove on top of the non toxic firelighters, place one or two small dry split logs (¼ split) on top. 2. Open air controls fully by sliding both levers to the left. The secondary air control is above the stove door and the primary control is below the door.
  • Page 8 BURNING WOOD IN A SMOKE CONTROL AREA You must purchase a smoke control version of the Mendip stove which is modified slightly to comply with regulations. Any change to this modification will invalidate the stoves compliance for smoke control areas. The Clean Air Act 1993 and Smoke Control Areas  Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a...
  • Page 9 Incomplete combustion If the air controls on your Loxton 3.2kW stove are closed too much incomplete combustion may lead to a build-up of hard, shiny soot on the inside of your stove and glass. To prevent sooting of the chamber and glass introduce:- 1) more secondary air, 2) check that your fuel is suitable and dry.
  • Page 10 MAINTENANCE Mendip stoves recommend that the Loxton 3.2kW model need to have the ash removed from the stove at regular intervals (weekly if used daily). Allowing the ash pan to over flow can impede the function of the stove and can cause possible damage to the stove grate and ash pan.
  • Page 11 Sweeping your chimney Ensure that your appliance, flue ways and chimney are swept regularly. This could be incorporated in the service regime of your appliance. Regular sweeping is essential and means at least once a year for smokeless fuels and a minimum of twice a year for wood , If a throat plate is incorporated, it is essential that the throat plate is removed and cleaned above, all ashes and debris should be removed.
  • Page 12 Chimney Fires If the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney fire does occur turn the air control setting to the minimum, and tightly close the doors of the stove. This should cause the chimney fire to go out in which case the control should be kept at the minimum setting until the fire in the stove has gone out.
  • Page 13 Loxton 3 June 2016 onwards À partir de juin 2016 Code Item Description EN Item Description FR M10300-06-00-00-01 Cast iron door complete Porte complete Steel Body Corps de chauff Acier M10300-06-01-00-01 Cast Iron Door Porte fonte M10300-02-00-99-00 Vermiculite brick set...
  • Page 14: Consignes Generales De Sante Et De Securite

    Ce manuel se réfère aux poêles énumérés ci-dessus. Ils ont été testés conformément à la norme EN 13240 et 13229. Nous vous remercions d'avoir choisi un nouveau poêle de Mendip Stoves et nous sommes certains que vous en serez enchantés.
  • Page 15: Cheminée Et Raccordement Au Poêle À Bois

    à-dire, plus de 160 mm x 160 mm. La société Mendip Stoves conseille l'utilisation d'un système de conduit de fumée de combustibles solides pour l'installation dans des cheminées existantes. Tous les systèmes de cheminée doivent être utilisés conformément au Règlement de construction approuvé.
  • Page 16: Air Direct Et Poele Etanche

    Il n'y a pas de règles européennes concernant la distance minimale des murs non-inflammables, Mendip Poêles recommande de laisser une distance d'au moins 100 mm à l’arrière et sur les côtés du poêle. Loxton 3 prennent l'air de combustion à partir d'une seule ouverture de 80mm sous le poêle, une fois la porte fermée l’amenée d'air fournit tout l'air de combustion de l'appareil.
  • Page 17: Chambres De Combustion

    CHAMBRES DE COMBUSTION La chambre de combustion Mendip, les panneaux de vermiculite sont conçus pour assurer le maximum d'efficacité et sont une partie intégrante du processus de combustion propre au poêle. La vermiculite ne doit pas être enlevée autrement que pour nettoyer le poêle.
  • Page 18: Comment Allumez Votre Poêle À Bois Mendip

    Votre poêle n’est pas conçu pour être utilisé avec la porte ouverte; la porte du poêle doit être maintenu fermée sauf pour allumer le poêle, ajouter du bois de chauffage ou enlever des cendres et ceci afin d'empêcher les gaz de combustion de fuir. COMMENT ALLUMEZ VOTRE POÊLE À...
  • Page 19 CONTROLES D'AIR, Loxton 3 Air secondaire a gauche ouvert/ a droit Bar d'aire terciaire. Pour le double combustion ferme Aire primaire A gauche ouverte. a droite BOIS DE CHAUFFAGE Pour une utilisation optimale de votre poêle, il est nécessaire d’utiliser du bois de chauffage de bonne qualité. Il faut bruler un bois de chauffage sec issu de bois de feuillus (la teneur en humidité...
  • Page 20 FONCTIONNEMENT PENDANT LA NUIT Mendip Stoves sont conçus pour brûler du bois et du Charbon sans fumée de qualité Comme un régime de temps de nuit, nous recommandons que la chamber de combusion est chargé quand il est chaud et brûlé...
  • Page 21: L'entretien Annuel

    MAINTENANCE Mendip Stoves recommande de nettoyer régulièrement votre poêle, retirez la cendre (hebdomadaire si l’utilisation est quotidiennement). Utiliser un cendrier rempli par trop de cendre peut entraver le fonctionnement du poêle et peut causer des dommages sur la grille du poêle et sur le cendrier. Pour enlever le bac à cendre, utiliser l'outil et l’accrocher sur le devant du cendrier.
  • Page 22 Seul les composants propres du fabricant, ou pièces de rechange recommandées et approuvées par des poêles Mendip doivent être utilisés pour l'entretien de l'appareil et la réparation. Toute modification non autorisée annulera la garantie du poêle et la conformité à la norme EN 13240. Balayer vos cheminées et feux de cheminée Assurez-vous que votre appareil, conduits de fumée et la cheminée sont balayés régulièrement.
  • Page 24 Distribué en France par la société / Distributed in France and Benelux by:- Eurostove SAS Centre d’Affaires Rue de L’horlogerie BP 60011 62401 Bethune Cedex Contact@eurostove.fr www.eurostove.fr Part of Eurostove group Mendip Stoves Ltd, 2016, ver 5 June 2018 CODE: M10300-49-00-99-00...
  • Page 25 Check out our full range of Heating Products Central Heating Controls Honeywell Heating Controls Danfoss Heating Controls Radiator Valves Fernox Sentinel Magnaclean Warmup underfloor heating Water Heaters Hand Dryers...