Configuration mode:
Mains types:
Current transformer:
Voltage transformer:
NO
Measuring time for currents to calculate
MAX and average values:
Measuring time for voltages calculate
MAX and average values:
Measuring time for frequency to calculate
MAX and average values:
Measuring time for power to calculate
MAX and average values:
Reset measured values / times:
LCD display:
Operating hours counter:
see extension module
Access code:
Serial number:
Software version:
Fig. 13
Diagrama de flujo
10 PHOENIX CONTACT
100
4NBL, 3NBL, 4BL, 3BL, 2BL , 1BL
Set primary current
Set secondary current
Primary side:
YES
Secondary side:
20' min; 30' min; 60' min; 2'' sec; 10'' sec; 5' min; 8' min; 10' min; 15' min
20' min; 30' min; 60' min; 10'' sec; 5' min; 8' min; 10' min; 15' min
20' min; 30' min; 60' min; 10'' sec; 5' min; 8' min; 10' min; 15' min
20' min; 30' min; 60' min; 10'' sec; 5' min; 8' min; 10' min; 15' min
MAX4I: Maximal value of the currents
MAXU: Maximal value of the conductor voltages (1-2 / 2-3 / 3-1)
MAXV: Maximal value of the conductor voltages against N (1 / 2 / 3)
MAXF: Maximal value of the frequncy
MAXP+: Maximal value of positive real power
MAXP-: Maximal value of negative real power
MAXQ+: Maximal value of positive reactive power
MAXQ-: Maximal value of negative reactive power
MAXS: Maximal value of appearent power
HOUR: Operating hours counter
EA+: Positive active energy (+kWh)
ER+: Positive reactive power (+kVArh)
ES: Appearent power (-kVAh)
EA-: Negative active energy (+kWh)
ER-: Negative reactive power (+kVArh)
AUX: illuminated, if supply voltage is available
I: illuminated, if current is being measured
U: illuminated, if voltage is being measured
for AUX: Illumination goes out automatically after 2 minutes.
The display is illuminated again after pressing any key.
AUX: activated, if supply voltage is available
I: activated, if threshold value is set (input current)
U: activated, if threshold value is set (input voltage)
E1: activated, if digital input 1 is connected
E2:
activated, if digital input 2 is connected
E3:
activated, if digital input 3 is connected
E4:
activated, if digital input 4 is connected
E5:
activated, if digital input 5 is connected
E6:
activated, if digital input 6 is connected
Threshold value:
Set value
Press
until you reach menu item Ser l :
serial number is displayed
Press
until you reach menu item SOFt:
software version is displayed
Set value
1 A; 5A
Set value
110; 115; 120; 173; 190; 60; 100
I / U
Set value
Yes; No