INSTALLATION
For field wiring information, please refer to the instructions attached to inside of front cover.
• Make sure that all unused taps (leads) are separately insulated.
• Check voltage at lamp terminals after installation. It should be 12 ± 0.3 VAC.
• Voltages above 12.3 VAC at the light may cause the internal safety fuse of the transformer to switch
off and on. To prevent this from happening follow chart below for correct voltage and wire
gauge selection.
Step 1 Select power source by adding up Bulb Watts
Step 2 Determine length of cable run(s)
Step 3 Determine wire gauge needed to deliver needed power
Step 4 Connect cable to output tap of transformer given in table
If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge.
This warranty is extended to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse
in handling, acts of God or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance
with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs, LED's and batteries; (f) the finish on any portion of the product, such as surface
and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR
IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,
ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE.
SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased or (b) completing a warranty claim online at www.
intermatic.com. This warranty is made by: Intermatic Incorporated, Customer Service 7777 Winn Rd., Spring Grove, Illinois 60081-9698. For warranty service go to: http://www.
Intermatic.com or call 815-675-7000.
Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material
contained herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.
INTERMATIC INCORPORATED, SPRING GROVE, IL 60081-9698
Pool/Spa Underwater Lighting Application
Transformer Cable -
Output Voltage Selection Chart
Power Source
Length of Cable
10 ft
12 VAC
20 ft
12 VAC 12 VAC
30 ft
12 VAC 12 VAC 12 VAC
50 ft
12 VAC 12 VAC 12 VAC 12 VAC
75 ft
13 VAC 12 VAC 12 VAC 12 VAC 12 VAC
100 ft
13 VAC 13 VAC 13 VAC 12 VAC 12 VAC
125 ft
150 ft
175 ft
200 ft
250 ft
Wire Gauge (AWG)
#18*
* MINIMUM GAUGE CABLE
** BLANK FIELDS INDICATE CONDITIONS NOT SUITED FOR WIRING
LIMITED ONE-YEAR WARRANTY
http://www.intermatic.com
PX50 Transformer
13 VAC 13 VAC 13 VAC 12 VAC
13 VAC 13 VAC 12 VAC
13 VAC 13 VAC
#16
#14
#12
13 VAC
13 VAC
#10
2