RIDGID MOBILAIR TRI-STACK OF50150TS Manuel D'utilisation page 10

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ASSEMBLY
WARNING:
If any parts are damaged or missing do not operate
this product until the parts are replaced. Use of
this product with damaged or missing parts could
result in serious personal injury.
WARNING:
Do not attempt to modify this product or create
accessories not recommended for use with this
product. Any such alteration or modification is
misuse and could result in a hazardous condition
leading to possible serious personal injury.
WARNING:
Do not connect to power supply until assembly
is complete. Failure to comply could result in
accidental starting and possible serious personal
injury.
ADJUSTING COMPRESSOR TANK HANDLE
INTO CARRY POSITION
See Figure 3, page 20.
 Using the wrench (included) remove screws from handle
brackets.
 Pivot handle into upright position for carrying.
 Reinstall screws securely through handle holes and
through handle bracket holes located on top of motor
housing on compressor tank.
RELEASING COMPRESSOR TANK FROM MAIN
TANK
See Figure 4, page 20.
 Make sure the air compressor is off and unplugged.
 Rotate pressure regulator knobs fully in the counterclock-
wise direction so that the outlet pressure is at zero (0) psi.
 Turn ball valve lever, on unregulated air hose, OFF
(90º). Be sure unregulated air hose is turned off before
connecting or disconnecting from unregulated air intake
coupler.
 Disconnect unregulated air hose.
 Push hose into unregulated air hose storage clip.
 Pull lock/release knob and turn counterclockwise to the
unlock position. Hooks will detach from pins and lower
beneath docking plate.
 Carefully lift and remove compressor tank from main tank.
ATTACHING COMPRESSOR TANK TO MAIN
TANK
See Figures 5 - 6, pages 20 - 21.
 Make sure the air compressor is off and unplugged.
 Rotate pressure regulator knobs fully in the counterclock-
wise direction so that the outlet pressure is at zero (0) psi.
 Pull lock/release knob and turn counterclockwise to the
release position. Hooks will lower beneath docking plate
on main tank.
NOTE: Lock/release knob is spring loaded in the unlock
direction.
 Lift compressor tank and center over main tank so that
the gauge panels face the same direction.
 Set compressor tank gently onto main tank.
 Turn lock/release knob clockwise to lock position. Hooks
on main tank will lock onto pins located on the underside
of compressor tank.
 Lift air compressor slightly to be sure compressor tank
and main tank are securely locked together.
 Attach 1/4 in. NPT quick-connect air fitting on unregulated
air hose to unregulated air intake coupler, located on top
of main tank. Make sure to push the hose fitting fully into
the coupler until the coupler sleeve locks it into place.
 Turn unregulated air quarter-turn ball valve lever on
unregulated air hose, ON (90º). This is the open position,
allowing air flow from the compressor tank into the main
tank.
10 – English

Publicité

Table des Matières
loading

Table des Matières