• If the electricity supply fails, do not use the devices connected to the
appliance.
• The appliance can discharge only faeces, toilet paper and acid fatty and hot
water (up to 100C°). Do not throw unsuitable objets, hygienic articles or
fibrous material that might damage the pump into the WC. For this reason, fix
the stiker supplied to the underside of the toilet lid or in some other position
where it is visible.
• Check that the items connected to the appliance are not leaking, since if
they are, the pump will operate uselessly.
Furthermore, in the event of a failure in the power supply, water leaking
from some device could flow back up and might then overflow.
• In the event that the bathroom or house are not to be used for a long
period, it is recommended that the mains water supply be closed.
• The pump is not damaged by detergents.
REMOVAL OF THE EXTRACTABLE PART FOR THE MACERATION ZONE CLEANING
MOD 600 comprises an initial water-collecting unit fixed in a permanent
manner onto the water closet and the other appliances, and a second extrac
table unit including the mechanisms needed for its operation.
The extractable part can be removed in a very simple operation as follows:
1.Disconnect the plug from the socket of the device.
2.Remove the side cover as shown in Fig. 7.
3.Remove the plug provided for emptying the collection unit, collecting the
water as shown in Fig. 8.
4.Unscrew the knob on the opposite side of the appliances as shown in Fig. 9.
5.Remove the extractable unit as shown in Fig. 10 and free the filter from any
unsuitable object as shown in Fig. 11.
6.Insert the extractable unit and screw back the knob until the extractable unit
is firmly connected to the water collection unit.