To access the advanced settings menu, open the general settings menu and enable the
'Advanced settings' switch, then select 'Advanced battery settings'.
The settings in the advanced menu (with expert mode disabled) include:
a) Battery preset
The 'Battery preset' dropdown allows selection from the following options:
i.
Built-in preset
Selection of a standard integrated pre-set (same as the general settings menu)
ii.
User defined
Reselection of the last 'user defined' charge settings
iii.
Select preset
Selection from an extended range of integrated battery charging pre-sets,
including new user defined charging pre-sets
iv.
Create preset
A new charging preset to be created and saved from user defined settings
v.
Edit presets
An existing preset to be edited and saved
b) Maximum charge current
The maximum charge current setting allows selection between the standard (full current)
or a significantly reduced charge current limit (varies per model - refer to specifications),
same as through the general settings menu.
c) Charge voltage
i.
Absorption, Float, Storage and Recondition voltage
The absorption, float, storage and recondition voltage settings enables the voltage
setpoint for each charge stage to be independently configured and some charge
stages (recondition and float) to be disabled or enabled.
d) Voltage compensation
i.
Temperature Compensation
The temperature compensation setting enables the charge voltage temperature
compensation coefficient to be configured, or temperature compensation to be
totally disabled (such as for Li-ion batteries).
The temperature compensation coefficient is specified in mV/°C and applies to the
entire battery/battery bank (not per battery cell).