FRONT PANEL
1
4 - Programming switch (pulse or hold mode for the Stop relay).
Pulse mode in upper position of the switch. (An incoming permanent information on the
input will cause a 100 ms closure of the Common and Work contacts of the Stop relay).
Hold mode in lower position of the switch. (An incoming permanent information on the
input will cause a permanent closure of the Common and Work contacts of the Stop relay
with a duration identical to that of the input information).
Note : The Hold mode must be selected when the input information is of the Pulse type,
be it superior or inferior to 100mS. The closure duration of the relay will be similar to
the duration of the pulse. The inputs are filtered against unwanted triggerings in
hostile environments (on CEM level). Please contact us for pulses inferior to 40 ms.
C - Stop relay state LED.
D - Start relay state LED.
Rami
2
3
4
5
6
7
15
8
9
10
Next
FDI1000