Télécharger Imprimer la page

DOTLUX 3923-1 Mode D'emploi page 9

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EN
Specially designed for retrofitting constant current LED luminaires. Can be operated in
continuous and standby mode. Constant power function ensures constant power (2.2 W/5
W) for different luminaires in emergency mode.
Battery discharge and charge specifications
Parameter
Output voltage
Constant output current
Emergency power
Output voltage
Constant output current
Emergency power
Setting the DIP switches on the unit
EM Leistung
ON
1
EM Power
5W
2.2W
OFF
24.2mm
Screw the battery kit to the grid ceiling using the fastening holes.
Test button
Max.
10 - 90 V DC
40 - 330 mA
4,8 - 5,2 W
10 - 90 V DC
22 - 195 mA
2,2 - 2,4 W
The reset plug must always be plugged in during ope-
ration. It prevents the battery from discharging during
transport. The system is reset by unplugging and
plugging it in.
215.8mm
250mm
LED holder small/
LED display green
Note
Both selector switches set to "EM
5 W" - measured at 6.4 V battery
voltage
Both selector switches set to „EM
2.2 W" - measured at 6.4 V battery
voltage
LED holder large