Failure
Batteries are not charged.
Switch is in wrong position
Light does not
turn on.
Rechargeable batteries are at the end
of their life.
Sensor is malfunctioning.
Possible Cause
Page 7 of 16
Corrective Action
Ensure the solar panel is in a location
where it will receive maximum sunlight
during daytime hours.
Turn the light to the OFF position and
allow the solar panel to charge the
batteries for 2 sunny days.
Clean the solar panel with a clean,
damp cloth.
Move the switch to the AUTO position.
Replace the batteries with new
rechargeable batteries of the same
type and size.
Battery Replacement:
1.
Batteries are located in the battery
housing located at the back of the
lamp.
2.
Remove Screws from front of the
battery housing to access
batteries.
3.
Replace batteries with
rechargeable batteries of the
same type and rating
4.
Reassemble battery housing.
Reset the Sensor:
1.
Take the light into a dark room and
then switch to the Auto.
2.
Activate the motion sensor in the
dark.
3. Once the light turns on, the
sensors are reset.
4. Wait until the light turns off before
returning the product to a lit room
or area.