EC Declaration of Conformity
Wolf ATEX Fluorescent Leadlamps meet all relevant provisions of the 94/9/EC
Explosive Atmospheres (ATEX Equipment) Directive by virtue of the issued EC type
examination certificate, demonstrating compliance with all relevant harmonised
standards and essential health and safety requirements.
The Wolf ATEX Fluorescent Leadlamp is a portable or fixed area light with a durable
enclosure construction of polycarbonate and polyurethane. The Fluorescent
Leadlamp models are available in a variety of input voltages. Approval is as Group II,
Category 2 equipment for use in zone 1 & 2 potentially explosive gases, vapours,
mists and dusts where the temperature class/maximum surface temperature permits.
Approval Codes/Certification:
II 2 GD
Ex emb II T3 -20ºC to +35ºC (4 x CFL lamps)
Ex emb II T3 -20ºC to +44ºC (2 x CFL lamps)
EX emb II T3 -15ºC to +53ºC (110V 2x CFL Emergency)
Ex emb II T4 -20ºC to +53ºC (2 x T8 lamps)
Ex tD A21 IP66/IP67/IP68 T100ºC (102ºC for 2x CFL Emergency)
2 x CFL -20ºC to +44ºC T3 incoming cable 36ºC above ambient
4 x CFL -20ºC to +35ºC T3 incoming cable 53ºC above ambient
2 x CFL Emergency -15ºC to +53ºC T3 incoming cable 33ºC above ambient
2 x T8 STD -20ºC to +53ºC T4 incoming cable 29ºC above ambient
2 x T8 EMER -15ºC to +53ºC T4 incoming cable 29ºC above ambient
When sockets are fitted the certification code changes to "embd IIC" and IP rating is
reduced to IP66. Some variants of plugs/sockets may reduce the maximum ambient
to 40ºC (except where ambient is below 40ºC already)
EC Type examination certificate: SIRA08ATEX3098X
Notified
Baseefa Ltd.
Body:
Rockhead Business Park, Staden Lane, Buxton, SK17 9RZ, UK
Notified body number: 1180
Harmonised standards applied:
EN60079-0:2009, EN60079-7:2007, EN60079-18:2009, EN61241-0:2006,
EN61241-1:2004.
Ingress protection level (Non-Linkable): IP66/IP67/IP68 to EN60529:1992.
(3m submersion for 30 minutes)
Ingress protection level (Linkable): IP66 to EN60529:1992. Do Not Submerge
All Ex sockets and Ex plugs used on Lead Lamps are IP66 rated,
Do not Submerge
Wolf Fluorescent Leadlamps are certified compliant with the 2004/108/EC
EMC Directive.
The product is CE marked showing compliance with all relevant EC Directives
Alex Jackson – Managing Director
Wolf Safety Lamp Company Ltd.
IMPORTANT
1. Read this leaflet carefully before commencing to use the luminaire and retain it for
future use.
2. Check the rating label to ensure the luminaire is suitable for the supply provided,
ambient temperature present and IP rating. ATEX certification includes assessment
of product safety at ±10% of rated voltage, running lamps outside of this voltage
tolerance will therefore invalidate the ATEX approval and the product warranty, may
result in a dangerous condition, and could cause the product to fail prematurely.
3. The luminaire housing is constructed from polycarbonate and polyurethane,
the end user must ensure that these materials are suitable for the atmosphere the
luminaire will be used in. Excessive force should not be used on plastic components.
4. Only luminaires using compact fluorescent lamps are suitable for portable
applications, luminaires using T8 lamps must be used in static applications only.
5. In areas where processes that induce circulating currents in the earth system are being
undertaken, such as welding, it is the user's responsibility to ensure there is no
potential difference between the supply earth and the earth local to the luminaire. If a
potential difference exists there is a risk of arcing should the lamp's end cap fixings or
metal gland come into contact with local metal work. In these situations, the luminaire
should also be locally earth bonded with a flexible cable, no longer than 2 metres, with
a conductor area of 6mm2 minimum. The luminaire must be de-energised during
connection or disconnection of the local earth bond.
WOLF SAFETY LAMP COMPANY
Saxon Road Works, Sheffield, S8 0YA, England
Tel: +44 114 255 1051
Fax: +44 114 255 7988
E-mail: info@wolf-safety.co.uk Website: www.wolf-safety.co.uk
LL-590 Issue 10
DF445
Wolf ATEX Fluorescent
Leadlamp LinkEx LL-500
Operation and Maintenance Instructions
Please Retain – Read Before Use
6. Damaged equipment should be withdrawn and repaired as necessary before
being put back in to service, in accordance with EN60079-17 code of practice.
Inspect cable at regular intervals.
7. Lamps must not be opened in Hazardous Areas.
8. This product is Class1 equipment and must be earthed. Luminaires are supplied
as standard with 3 core earthed supply cables. Where the user specifically
requires a 24 volt SELV luminaire with 2 core cable (+ve and -ve) / a 2 pole plug,
the luminaire must be used with a separate connection to earth via the external
earth grounding point.
SPECIAL CONDITIONS FOR USE
Linkable models fitted with Marechal sockets, sockets must not be exposed to
mechanical impact higher than 4 Joules.
INSTALLATION
1. When luminaires are used in fixed installations two mounting points must be
used, the two end caps on each luminaire have four mounting points which are
compatible with Unistrut
can also be carried around whilst illuminated using the carrying strap supplied.
2. All luminaires have terminal blocks suitable for 4mm
conductor should be fitted to each terminal block, for screwed type terminal blocks
all terminals should be fully tightened down whether a conductor is fitted or not.
3. Approved cable glands must be used and be suitable for the type of cable used.
Any unused cable entries should be blanked off with an approved stopper plug
to maintain a minimum IP rating as marked on the certification label.
MAINTENANCE
1. Isolate the luminaire from both switched and unswitched mains supplies before
carrying out any maintenance work.
2. Lamps must be changed at the intervals recommended by the lamp manufacturer.
3. It is essential that all luminaires are maintained in accordance with the
requirements of EN60079-17.
4. External plastic components have an anti static coating to avoid a build up
of static electricity, use only a dilute water/detergent mix to clean luminaires
5. IMPORTANT. No modifications are permitted to the luminaire, all spare parts
must be purchased from the manufacturer, unauthorized modifications or spare
parts will invalidate certification.
ELECTRICAL DATA
Total circuit watts 2x55/58W = 92W, 2x36W = 62W, 2x18W = 32W, 4x55W
= 185, 4x36W = 125W, 4x18W = 65W . Power factor correction better than 0.95.
Inrush current on initial switch on 45A for 500
to exceed 16A. HV insulation testing may be carried out at voltages less than 500V
DC, live and neutral cables should be shorted together and the voltage applied
between earth and this connection.
CHANGING LAMPS
Isolate the luminaire, remove an end cap by releasing the two recessed screws within
the end cap, the clear polycarbonate tube can now be withdrawn over the internal
reflector. The lamps are removed by releasing the two lamp retainers on each lamp and
then removing the two screwed connectors from the end of each lamp. Fitting lamps is
a reversal of the above procedure check that the silicone gasket is seated within the end
cap before assembly. Use only compact fluorescent lamps with 2G11 bases, for T8
fluorescent lamp variants G13 caps are required for bi pin and Fa6 caps for single pin.
EMERGENCY LUMINAIRES
Emergency luminaires should be charged/discharged three times upon commissioning
to ensure the batteries are cycled to their peak capacity, charging time shall be a
minimum of 24 hours. The luminaires are designed to give approx. three hours light
output during a power failure, the luminaires should be tested on a regular basis
in accordance with national standards on emergency lighting. When on battery
power only one tube will illuminate and this will be at a reduced power level.
The lamp will come on every time the supply is removed. If the lamp has been
powered for only a short time the battery duration will be proportionally reduced.
Ensure battery is fully discharged before dismantling the lamp to replace the tubes.
FAULT FINDING
If luminaire fails to function, replace fluorescent tubes.
DISPOSAL OF WASTE MATERIAL
Disposal of packaging, luminaire and old lamps should be carried out in accordance
with national regulations.
WARNING: USE ONLY GENUINE WOLF REPLACEMENT PARTS.
The Wolf Safety Lamp Co. Ltd has a policy of continuous product improvement.
Changes in design details may be made without prior notice.
and associated accessories. Portable luminaires
®
live, neutral and earth. Only one
2
. Maximum luminaires on a circuit not
µs
MMD/???/12.15/??K

Publicité

loading

Sommaire des Matières pour Wolf ATEX LinkEx LL-500

  • Page 1 3 core earthed supply cables. Where the user specifically The Wolf ATEX Fluorescent Leadlamp is a portable or fixed area light with a durable requires a 24 volt SELV luminaire with 2 core cable (+ve and -ve) / a 2 pole plug, enclosure construction of polycarbonate and polyurethane.
  • Page 2 Les luminaires sont fournis à l'origine avec des câbles d'alimentation tripolaires La lampe déphasée fluorescente Wolf ATEX est une lampe fixe ou portative équipée d’un raccordés à la terre. Si l'utilisateur demande un luminaire SELV 24 V avec un câble à...
  • Page 3 Fluorescent Leadlamp LinkEx LL-500 EU Declaration of Conformity Addendum The Wolf ATEX Fluorescent Leadlamp LinkEx LL-500 meets all relevant provisions of the 2014/34/EU Explosive Atmospheres (ATEX Equipment) Directive by virtue of the issued EC Type Examination Certificate, and subsequent review confirming compliance with all relevant Harmonised Standards and Essential Health and Safety Requirements.