Cadac 2 COOK 2 PRO Mode D'emploi page 4

Masquer les pouces Voir aussi pour 2 COOK 2 PRO:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
Country of Use
Appliance Catagories
Allowable gasses
Gas Pressure
Jet Number
Nominal Usage
Gross nom. heat input
AE = United Arab Emirates
CZ = Czech Republic
FR = France
JP = Japan
PT = Portugal
SK = Slovakia
3. Assembly Instructions
PLEASE NOTE: Please ensure all protective packaging and plastic are removed from the appliance before use.
This appliance may only be used with an approved hose and regulator (hose and regulator supplied with this unit in South Africa)
Connect the regulator to a CADAC 3kg, 5kg or 7kg LPG cylinder prior to use.
If you wish to use the appliance with a 9kg cylinder, please ensure that you have purchased the correct hose and regulator suitable for a
9kg cylinder.
The hose length should be no less than 0.8m and shall not exceed 1.2 m and replace when the hose is damaged or shows signs of
brittleness or cracks.
Do not twist or pinch the hose. Ensure that it is routed away from the Stove Body so as to prevent deterioration / damage to the hose
caused by heat.
Ensure that the appliance valves are in the off position by turning the knobs fully clockwise to the stop.
Open the gas valve on the cylinder and test for any leaks.
Check all gas connections for any signs of gas leaks.
Your appliance is now ready to be used.
I 3B/P (30), I 3+ (28-30/37) and I 3B/P (37), Appliance categories: (DK, FI, NO, NL, SE, AT, DE, BE, ES, FR, IE, IT, PT, GB, CH)
Push an approved hose onto the valve tailpiece until it is properly seated. On the other end, attach a suitable low pressure regulator.
I3B/P(30) : 30mbar Butane configurations regulator or 30mbar Propane configurations regulator.
I3B/P(37) : 37mbar Butane configurations regulator or 37mbar Propane configurations regulator.
I3+(28-30/37) : 30mbar Butane configurations regulator or 37mbar Propane configurations regulator.
Again making sure that the hose is properly seated. The type of hose used shall comply with the relevant EN standard and locate
requirement. In South Africa the regulator used must comply with SANS 1237.
I 3B/P (50) Appliance category: (AT, DE)
I3B/P(50) : 50mbar Butane configurations regulator or 50mbar Propane configurations regulator or 50mbar butane/propane mixture
configurations regulator.
Screw a hose with the correct threaded fittings on each end, onto the left hand 1/4" BSP thread of the valve. Attache a suitable 50mbar
low-pressure regulator on the end of the hose. The hose assembly used must comply with DIN 4815 part 2 or equivalent.
BE, CH, CY, CZ, ES, FR, GB, GR,
IE, IT, LT, LU, LV, PT, SK & SI
I
3+(28-30/37)
Butane-G30
Propane-G31
28-30mBar
37mBar
0.71
Butane - 145.5 g/h
per burner
(145.5g/h x 2 = 291g/h in total)
2kW per burner
(2kW x 2 = 4kW in total)
Country Name and Abbreviations
AL = Albania
AT = Austria
DE = Germany
DK = Denmark
GB = United Kingdom
GR = Greece
KR = Korea
NL = Netherlands
RO = Romania
RU = Russia
SE = Sweden
TR = Turkey
PL
I
3B/P (37)
Butane-G30, Propane-G31 or their mixture
37mBar
0.71
Butane - 160 g/h
Butane - 145.5g/h
per burner
(160g/h x 2 = 320g/h
in total)
2.2kW per burner
(2.2kW x 2 = 4.4kW
in total)
BE = Belgium
ES = Spain
HR = Croatia
NO = Norway
RS = Serbia
ZA = South Africa
2 2
BE, CY, DK, EE,
FR, FI, HU, IT, LT,
NL, NO, SE, SI,
AT, CH, DE & SK
SK, RO, HR, TR,
BG, IS,LU, MT
,
& ZA
I
I
3B/P (30)
3B/P (50)
28-30mBar
(2.8kPa for South
50mBar
Africa)
0.71
Butane - 145.5g/h
per burner
per burner
(145.5g/h x 2 =
(145.5g/h x 2 =
291g/h in total)
291g/h in total)
2kW per burner
2kW per burner
(2kW x 2 = 4kW
(2kW x 2 = 4kW
in total)
in total)
CH = Switzerland
FI = Finland
IT = Italy
PL = Poland
SI = Slovenia
GB
0.62

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

202p1202p0

Table des Matières