Teka FS 901 5GE SS LPG Mode D'emploi page 20

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
Reduced gas flow rate setting for hob taps
1. Ignite the burner that is to be adjustment and turn the knob to the
reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to adjust the flow rate adjustment
screw. For LPG (butane-pro pane) turn the screw clockwise. For the
naturel gas, you should turn the screw counter- clockwise once.
"The normal length of a straight flame in the reduced position should
be 6-7 mm."
4. If the flame is higher then the desired position, turn the screw clockwise.
If it is smaller turn anticolockwise.
5. For the last control, bring the burner both to higt-flame and reduced
positions and check whether the flame is on or off.
Depending on the type of gas tap used in your appliance the adjustment
screw position may vary.
To adjust your oven acc. to the gas type, make the adjustment for
reduced flame carefully by turning with a small screwdriver as shown
below on the screw in the middle of the gas cocks as well as nozzle
changes (figure 6 and 7).
Figure 6
20
Figure 7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fs 902 5gg ss lpg

Table des Matières