Pressing the power switch,
the machine won't start.
The brush does not rotate.
Aspirator does not work.
The machine does not dry
well, leaving traces of water
on the floor.
No water comes out.
3

TROUBLESHOOTING

PROBLEM
CAUSE
Low battery.
Main fuse blown.
Brush fuse blown.
The brush rotation switch
isn't pressed.
Aspirator fuse blown.
The vacuum switch is not
pressed.
Recovery tank full.
Aspirator off.
Aspiration tube blocked.
Recovery tank full.
Squeegee
rubber
blades
worn.
Tank empty.
The solenoid switch is not
pressed.
Tap turned off.
Filter blocked.
Solenoid valve does not
work.
EN-27
SOLUTION
Check that the battery is
charged.
Replace the fuse.
Replace the GREEN 30A
brush motor fuse.
Press the switch.
Replace the GREEN 40A as-
pirator motor fuse.
Press the switch.
Empty, wash and clean the
tank and the probes.
Start up the aspirator.
Check
and
if
necessary
clean the aspiration tube that
connects the squeegee to
the recovery tank.
Empty the recovery tank.
Replace or turn over the
squeegee rubber blades.
Fill the tank.
Press the switch.
Open the valve placed at the
top of the device.
Clean the filter.
Call the technical support
service.