FONESTAR ZSC-1110 Mode D'emploi page 4

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
6.- CHIME VOL: chime volume control.
7.- BASS: reinforces or attenuates bass frequencies in LINE 1/2 IN and MIC 1/2 inputs.
8.- TREBLE: reinforces or attenuates treble frequencies in LINE 1/2 IN and MIC 1/2 inputs.
9.- AUDIO OUT: line output for paging from remote microphone mod. ZS-11, the microphone inputs MIC
1/2 or the audio inputs LINE 1/LINE 2 when the contacts ALARM IN A/B are closed.
10.- LINE 1/LINE 2 IN: line inputs for alarm paging. These inputs are activated when the ALARM IN A/B
contacts are closed. The priority level of the different inputs is as follows: LINE IN 2 → MIC1/2 → LINE IN
1, 10 kΩ euroblock connectors.
11.- MIC 2 IN: unbalanced microphone input with 6.3 mm jack connector, 600 Ω.
12.- SPEAKER OUT 100 V CH 1-CH 10: Zones 1-10 output, to connect the corresponding loudspeakers to
each zone, euroblock connectors.
13.- ALARM OUT A/B: alarm output contacts. These contacts close automatically when the ALARM IN A/B
input contacts are closed.
NOTE: if you have more than one ZSC-1110 zone system, it is recommeded that the ALARM OUT A/B
output is connected to the ALARM In A/B input of the following zone system.
14. ALARM IN A/B: alarm input contacts. When these contacts are closed the audio line inputs LINE 1/LINE
2 will be activated and all the zones will be activated for paging.
- 4 -

Publicité

Table des Matières
loading

Table des Matières