6.3 Switching off the engine
Before you switch off the generator, allow it
to run briefly with no consumers so that it can
„cool down"
Move the ON/OFF switch (10) to position
„OFF" with the key.
Close the petrol cock

6.4 Overload cut-out

The generator is fi tted with an overload cut-out.
This isolates the relevant sockets if an overload
occurs.
Important. If this happens, reduce the electric
power you are taking from the generator or remo-
ve any defective connected appliances.
Important. Defective overload cut-outs must be
replaced only by overload cut-outs of identical
design and with the same performance data. If
repairs are necessary, please contact your custo-
mer service center.
230V~ sockets
If an overload occurs, the 230V~ sockets (Fig. 3/
Item 3) will be isolated from the supply. You can
restart the 230V~ sockets by pressing the over-
load switch (Fig. 3/Item 5).
400V 3~ socket
If an overload occurs, the 400V 3~ socket (Fig. 3/
Item 24) will be isolated from the supply. You can
restart the 400V 3~ sockets by pressing the over-
load switch (Fig. 3/Item 26).
7. Cleaning, maintenance, storage
and ordering of spare parts
Switch off the motor and pull the spark plug boot
from the spark plug before doing any cleaning
and maintenance work on the equipment.
Notice! Switch off the machine immediately and
contact your service station:
In the event of unusual vibrations or noise
If the engine appears to be overloaded or
misfires
7.1 Cleaning
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
Anl_SE_3000_SPK7.indb 21
Anl_SE_3000_SPK7.indb 21
GB
We recommend that you clean the device
immediately each time you have finished
using it.
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use
cleaning agents or solvents; these could
attack the plastic parts of the equipment. En-
sure that no water can seep into the device.
7.2 Air fi lter
In this connection, please also read the service
information.
Clean the air filter at regular intervals, and
replace it if necessary.
Open both clips (Fig. 11/A) and remove the
air filter cover (Fig. 11/B).
Remove the filter elements (Fig. 12/C)
Do not use abrasive cleaning agents or petrol
to clean the elements.
Clean the elements by tapping them on a flat
surface. In cases of stubborn dirt first clean
with soapy water, then rinse with clear water
and air-dry.
Assemble in reverse order
7.3. Spark plug (Fig. 13-14)
Check the spark plug for dirt and grime after 20
hours of operation and if necessary clean with a
copper wire brush. Thereafter service the spark
plug after every 50 hours of operation.
Open the maintenance flap (Fig. 13).
Pull off the spark plug boot with a twist.
Remove the spark plug (Fig. 14/D) with the
supplied spark plug wrench.
Assemble in reverse order
7.4 Changing the oil and checking the oil le-
vel (before using the machine)
The motor oil is best changed when the motor is
at working temperature.
Only use motor oil (15W40).
Place the generator on a slightly inclined sur-
face so that the oil drain plug is at the lower
end.
Open the oil filler plug.
Open the oil drain plug and let the hot engine
oil drain out into a drip tray.
After the old oil has drained out, close the oil
drain plug and place the generator on a level
surface again
Fill in engine oil up to the top mark on the oil
dip stick.
Important: Do not screw the dipstick in to
check the oil level, simply insert it up to the
thread.