Franklin Electric SubDrive Solar Manuel D'installation page 37

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Current Status Registers
The following registers are used for the SD-XXXX for current operational status.
H. #
Register Description
100
Buss Power / Daily (uint 16)
101
Buss Power / Cumulative (uint 32) lower word
102
Buss Power / Cumulative (uint 32) upper word
103
Buss Power / instantaneous (uint 16)
104
Drive State (uint 16)
Error State (uint 16)
105
DTR update with new error
106
Motor speed (uint 16)
107
Buss Voltage (uint 16)
108
Smart Reset Rule Time Method (uint 16)
109
FIXED_RULE_TIME (uint 16)
110
UNDERLOAD_TRIP_LEVEL (uint 16)
111
Demand input mode
112
Current (uint 16)
113
Run time (uint 32) lower word
114
Run time (uint 32) upper word
115
Drive status flags (uint 16)
Data Range
R/W Factory
0 - 9999 kwh
Read
0 - 999,999 kwh
Read
0 - 9999 watts
Read
0 = Standby
1 = Running
2 = Error
0 = None
1 = Underload
2 = Under voltage
3 = Locked rotor
4 = Miswired
Read
5 = Open phase
6 = Short phase
7 = Over temp
8 = Internal error
0 - 9999 Hz
Read
0 - 999 Vdc
Read
0 = Dynamic
R/W
1 = Fixed
5 - 80
R/W
Increments of 5
30 - 100%
R/W
0 = Dual input
R/W
1 = Single input
0 - 99.9 amps
Read
Minutes
Read
B3 = DC power
B4 = AC power
B5 = Flow switch
Read
B6 = Stop switch
B7 = Run switch
R/W Public
Read
Read
Read
Read
Read
Read
R/W
R/W
R/W
R/W
Read
Read
Read
37

Publicité

Table des Matières
loading

Table des Matières