RF basic thermostat WFHTRF 010 (20433)
TECHNICAL CHARACTERISTICS
Measured temperature precision
0.1°C (or 0.2°F)
Operating temperature
0°C - 50°C (or 32°F – 122°F)
Setting temperature range
5°C - 37°C by 0.5°C step (or 41°F - 99°F by 0.5°F step)
Proportional Integral regulation (PWM)
Regulation characteristics
(adjustable see installation menu) Cycle
Anti-short cycle: 3min in OFF, 2min in ON.
Electrical Protection
Class II - IP30
Power Supply
2 x 3V (CR2430)
Battery operated life
~ 2 years
Radio frequency
433.92 MHz, <10mW.
certifications
CE. EN 300220-1, EN 301489-1
Software version
Displayed during 5s when the thermostat is turn Off 3 x x
MODE DESCRIPTION
Use
key to change the mode in the Operating mode menu
OFF mode:
Use this mode if your Heating installation needs to be turned OFF.
The display is blank and all parameters are saved. (Careful in this mode your installation can freeze)
COMFORT operating mode:
Force comfort temperature operation indefinitely. By pressing keys
blink and can be adjusted. The measured temperature
REDUCED operating mode:
Force reduced temperature operation indefinitely. By pressing
blink and can be adjusted. The measured temperature
RADIO CONFIGURATION MODE
To assign (*) the RF thermostat with the receiver you must put the receiver in "RF init" mode
(Please refer to the receiver leaflet).
After you have just Press
key during 5 sec, when the display (rF""). The thermostat sends its
configuration address by radio signal.
When the receiver is configured, Press
* (In this mode the thermostat should be near the receiver)
Optional external
sensor 10K at 25°C
or
the comfort temperature starts to
reappears after a few seconds.
or
keys the comfort temperature starts to
reappears after a few seconds.
key to return to user menu.
GB
DISPLAY
1: Operating mode menu.
2: Heater indication.
3: Cooler indication.
4: Batteries weak.
5: If lit-up 6 displays the measured temperature
6: Measured temperature or setting temperature.
7: °C or °F indicator.
8: Moving bars when transmitting a radio signal
Or Title for installation Parameters (rF, J0,CLr...)
INSTALLATION PARAMETERS MENUS
Press the
key during 5 seconds, then use
adjusted.
Press
to toggle the parameter setting or edit the value.
If the value starts to blink you can use
Press
and
keys at the same time to reset this value to the factory default value. Once you have
adjusted the value press
Parameter
Description of the parameter
names
Radio configuration mode (see section) and
rF""
exit the installer's menu
J0
Select a type of degrees on the display
J1
Operating mode.
Proportional Integral regulation time cycle value in
Cy
minutes
bp
Value of the proportional band in °C
Anti-lock-braking function of the pump
J5
When the pump hasn't worked on a particular day, start
it up for one minute each day
J6
Selection of the sensor for regulation.
J7
Selection of regulation type
Cp
Value of the compensation in°C
Calibration of the internal sensor
(The calibration must be done after 15 minutes working
A0
with the same setting temperature. Check the room
temperature with a thermometer and enter the reel
value)
Calibration of the external sensor (if connected)
F0
(The calibration must be done same as above)
Lower limit of the floor temperature. Only effective if the
FL
external sensor is connected and selected.
Upper limit of the floor temperature. Only effective if the
FH
external sensor is connected and selected.
This parameter allows you to choose the works
Clr
adjustments
1
2
3
4
5
or
keys to select the installation parameter to be
or
keys to adjust this value.
to validate this parameter value.
Default setting
°C
« Hot »
For heating system
« 15 »
Slow system adapted
to each heating type
« 2.0°C / 3.6°F»
«Pmp»
« Air »
Room sensor only
or
Room sensor with
floor limitation if the
external sensor is
connected
« rEg »
Proportional band
(PWM)
« 2.0°C / 3.6°F»
Air sensor + 0°C
Floor sensor + 0°C
« 5°C / 41°F »
« 28°C / 82°F »
Press
8
7
6
Other possibility
Press
°F
Cld
For cooling system
Heating application :
Burner oil « 20 »
Burner gas « 10 »
Heat pump « 20»
Adjustable 1°C to +7°C
A well insulated house « 1.5C »
A not insulated house « 4°C »
no
« Flr »
External sensor only
Without limitation
« hys »
Static differential of 0.3°K
Adjustable 1°C to 8°C
From -5°C to +5°C
From -5°C to +5°C
From 5°C to « FH »
From « FL »to 37°C
during 5 seconds
PPL IMP 1011 B

Publicité

loading

Sommaire des Matières pour TBS WFHTRF 010

  • Page 1 USER GUIDE DISPLAY RF basic thermostat WFHTRF 010 (20433) 1: Operating mode menu. 2: Heater indication. 3: Cooler indication. 4: Batteries weak. 5: If lit-up 6 displays the measured temperature 6: Measured temperature or setting temperature. 7: °C or °F indicator.
  • Page 2 GUIDE D’UTILISATION AFFICHEUR Thermostat Digital RF WFHTRF 010 (20433) 1: Mode de fonctionnement 2: Indicateur de chauffe 3: Indicateur de refroidissement 4: Témoin batteries faibles. 5 : Si le symbole est présent, la température ambiante est affichée en (6) 6: Montre la température ambiante ou la consigne.

Ce manuel est également adapté pour:

20433