PRIVATE ONE – DOCUMENTATION TECHNIQUE
40008
07
40009
08
40010
09
40011
10
40012
11
40013
12
40014
13
40015
14
40016
15
40017
16
40018
17
40019
18
40020
19
40021
20
15 = NotResponding
Always
R
Charge Status :
0 = Unknown,
1 = WaitEnabled,
2 = Mode1_On,
3 = Mode1_LockError,
4 = Mode3_A,
5 = Mode3_B_no_pwm,
6 = Mode3_B_pwm,
7 = Mode3_C,
8 = Mode3_D,
9 = Mode3_CD_to_B,
10 = Mode3_E,
11 = Mode3_F,
12 = Mode3_PP_Error,
13 = Mode3_Lock_Error,
14 = Mode3_Ventilation_Error
Always
R
CanBeRegulated :
0 = the charger can't be regulated,
1 = the charger can accept current regulation command
Optional
R/W
Regulated Current : controls how many amps that the charger
can deliver to the vehicle in 100 milliamps.
14.5A
Optional
R
Maximum Current: Maximum current in 100 milliamps that the
charging borne can deliver
Example: 160 = 16A
Optional
R
Minimum allowed regulated current: Minimum current in 100
milliamps that the charging borne should deliver (Generally >
6A). Below this level, the charge will be stopped.
= 6A
Optional
R
Maximum allowed regulated current: Maximum current in
100 milliamps that the charging borne should deliver.
Generally same value as Maximum Current.
Example: 160 = 16A
Optional
R
CanProvideEnergyConsumption :
0 = No,
1 = Yes, absolute value,
2 = Yes, relative value (manually reset with 0x06 register)
Optional
R
Energy Consumption in Wh (unsigned integer 32bit)
Optional
W
Set Energy Consumption in Wh (unsigned integer 32bit): if 0,
reset the energy consumption. If other value, the written value
should be added to current value (used when the charger does
not have a persistent energy consumption mechanism).
Optional
R
Instant energy consumption in W
Optional
R
Instant current consumption in amps
Page 21
Example: 145 =
Example: 60