General information

HOOD EXHAUST

NOTE
Read these next two pages only if you plan to vent your exhaust to the outside. If
you plan to recirculate the air back into the room, proceed to page 12.
OUTSIDE TOP EXHAUST (EXAMPLE ONLY)
The following chart contains an example of one possible ductwork installation.
DUCT PIECES
Roof Cap
12 Ft.
Straight Duct
(6˝ Round)
Rectangular-
to-Round
Transition
Adaptor*
Equivalent lengths of duct pieces
are based on actual tests and reflect
requirements for good venting
performance with any vent hood.
IMPORTANT:
If a rectangular-to-round transition adaptor is used, the bottom corners of the
damper will have to be cut to fit, using the tin snips, in order to allow free
movement of the damper.
4 English
Install_ME11A7510DG_AC_DE68-04709B-00_EN+CFR.indb 4
Install_ME11A7510DG_AC_DE68-04709B-00_EN+CFR.indb 4
EQUIVALENT
NUMBER
EQUIVALENT
x
=
LENGTH
USED
LENGTH
24 ft.
x
(1)
=
12 ft.
x
(1)
=
5 ft.
x
(1)
=
Total Length =
OUTSIDE BACK EXHAUST (EXAMPLE ONLY)
The following chart contains an example of one possible ductwork installation.
DUCT PIECES
Wall Cap
3 Ft. Straight
Duct
(3 ¼˝ x 10˝
Rectangular)
24 ft.
90° Elbow
12 ft.
Equivalent lengths of duct pieces
are based on actual tests and reflect
requirements for good venting
performance with any vent hood.
5 ft.
NOTE
For back exhaust, care should be taken to align the exhaust with the space
between studs, or the wall should be prepared at the time it is constructed by
41 ft.
leaving enough space between the wall studs to accommodate exhaust.
EQUIVALENT
NUMBER
EQUIVALENT
x
=
LENGTH
USED
LENGTH
40 ft.
x
(1)
=
3 ft.
x
(1)
=
10 ft.
x
(2)
=
Total
=
Length
40 ft.
3 ft.
20 ft.
63 ft.