Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
2016 Gees Mill Road, Suite 200, Conyers, GA 30013
888-994-7636, fax 888-864-7636
unifiedbrands.net
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ,
UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS
CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WARNING R290 flammable refrigerant in use. Improper installation,
adjustment, alteration, service or maintenance can cause property
damage, injury or death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the
consignee to inspect the container upon receipt of same and to determine
the possibility of any damage, including concealed damage. Unified
Brands suggests that if you are suspicious of damage to make a notation
on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
EQUIPMENT DESCRIPTION
MODEL
LENGTH
DCHFT-45-SR6
45"
DCHFT-57-SR8
57"
DCST-36-SR7
36"
DCST-44-SR9
44"
DCST-54-SR11
54"
DCFT-36-SR7
36"
DCFT-44-SR9
44"
DCFT-54-SR11
54"
INSTALLATION
CAUTION: THIS UNIT CONTAINS R290 FLAMMABLE REFRIGERANT. USE CAUTION WHEN
HANDLING MOVING AND USE OF THE REFRIGERATOR OR FREEZER. AVOID
DAMAGING THE REFRIGERANT TUBING OR INCREASE THE RISK OF A LEAK.
WARNING: IT IS IMPORTANT THAT YOUR UNIT HAS ITS OWN DEDICATED LINE.
CONDENSING UNITS ARE DESIGNED TO OPERATE WITH A VOLTAGE
FLUCTUATION OF PLUS OR MINUS 10% OF THE VOLTAGE INDICATED ON
THE UNIT DATA TAG. BURN OUT OF A CONDENSING UNIT DUE TO EXCEEDING
VOLTAGE LIMITS WILL VOID THE WARRANTY.
THE DANFOSS CONTROLLER HAS LOW VOLTAGE PROTECTION AND WILL NOT
OUTPUT VOLTAGE TO THE COMPRESSOR IF VOLTAGE IS LESS THAN 104V.
STORAGE
DEPTH
HEIGHT
(GALLONS)
33"
36"
33"
36"
30"
36"
30"
36"
30"
36"
30"
36"
12 gal
30"
36"
18 gal
30"
36"
24 gal
Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends
referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications. © 2020 Unified Brands.
All Rights Reserved. Unified Brands is a wholly-owned subsidiary of Dover Corporation.
This manual provides information for:
DIPPING CABINET SERIES
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE: Due to a continuous program of product improvement, Unified Brands
reserves the right to make changes in design and specifications without prior notice.
NOTICE: Please read the entire manual carefully before installation. If certain
recommended procedures are not followed, warranty claims will be denied.
MODEL NUMBER _________________________
SERIAL NUMBER _________________________
INSTALLATION DATE ______________________
The serial number is located in the cabinet left side
under the drawer track. An example is shown here.
LID TYPE
COMPRESSOR
24
FLIP
36
FLIP
12
SLIDE
18
SLIDE
24
SLIDE
FLIP
FLIP
FLIP
WARNING: FAILURE
RECOMMENDATIONS MAY VOID THE WARRANTY ON YOUR UNIT.
WARNING: THIS UNIT IS INTENDED FOR USE IN LABORATORIES IN COMMERCIAL,
INDUSTRIAL, OR INSTITUTIONAL OCCUPANCIES AS DEFINED IN THE
SAFETY STANDARD FOR REFRIGERATION SYSTEMS, ASHRAE 15.
PART NUMBER PP MNL1910, REV. A (03/20)
VOLT
AMPS
1/3
115
3.2
1/3
115
3.2
1/3
115
3.2
1/3
115
3.2
1/3
115
3.2
1/3
115
3.2
1/3
115
3.2
1/3
115
3.2
TO
FOLLOW
INSTALLATION
SHIP WT
NEMA
(LBS)
5-15P
418
5-15P
458
5-15P
259
5-15P
390
5-15P
490
5-15P
259
5-15P
390
5-15P
490
GUIDELINES
AND

Publicité

Table des Matières
loading

Sommaire des Matières pour Randell DCHFT-45-SR6

  • Page 1 An example is shown here. Manufacture Service/Questions 888-994-7636. EQUIPMENT DESCRIPTION STORAGE SHIP WT MODEL LENGTH DEPTH HEIGHT LID TYPE COMPRESSOR VOLT AMPS NEMA (GALLONS) (LBS) DCHFT-45-SR6 45" 33" 36" FLIP 5-15P DCHFT-57-SR8 57" 33" 36" FLIP 5-15P DCST-36-SR7 36" 30" 36"...
  • Page 2: Installation Checklist

    IMPORTANT - READ FIRST - IMPORTANT NEAR EXPOSED REFRIGERANT TUBING INTERIOR EVAPORATOR COVER DANGER CAUTION RISQUE D’INCENDIE OU WARNING ALERTE MISE EN GARDE RISQUE D’EXPLOSION. D’INCENDIE OU INFLAMMABLE D’EXPLOSION EN RAISON RÉFRIGÉRANT UTILISÉ. DO NOT REMOVE PANEL - HIGH VOLTAGE - DE LA PERFORATION DU QUALIFIED PERSONNEL ONLY RISK OF FIRE OR EXPLOSION DUE TO...
  • Page 3: Manual Defrost

    MANUAL DEFROST It is recommended that the customer contact the local Authorized Service Agent to provide a quote to perform periodic Preventative Maintenance. MONTHLY PROCEDURES Clean fan blades on the condensing unit and evaporator assembly. RECOMMENDED CLEANERS FOR YOUR STAINLESS STEEL INCLUDE THE FOLLOWING: CLEANING AGENT COMMENTS...
  • Page 4 TROUBLESHOOTING SERVICE This unit is designed to operate smoothly and efficiently if properly maintained. CAUTION: COMPONENT PARTS SHALL BE REPLACED WITH FACTORY OEM PARTS. However, the following is a list of checks to make in the event of a problem. Wir- SERVICE WORK SHALL BE DONE BY FACTORY AUTHORIZED SERVICE ing diagrams are found at the end of this manual.
  • Page 5: Parts List

    REFRIGERATION PACKAGE Parts List CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 DCST-36 / DCST-44 / DCST-54 / ITEM SERVICE PART DESCRIPTION DCHFT-45 DCHFT-57 DCFT-36 DCFT-44 DCFT-54 RF CMP1701 COMPRESSOR, 1/3HP, R290, EMBRACO 115V-60HZ RF CMP1701SC COMPRESSOR, START COMPONENTS RP CAP1902 CAP, TUBE RF FAN1401 CONDENSER FAN RF FAN0703...
  • Page 6 BASE Parts List CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 DCST-36 / DCST-44 / DCST-54 / ITEM SERVICE PART DESCRIPTION DCHFT-45 DCHFT-57 DCFT-36 DCFT-44 DCFT-54 RP CNT1925C CONTROLLER, DANFOSS PREPROGRAMMED RF CNT1603 THERMISTOR, QTI, AIR SENSOR, BLACK, 10' RP CVR2001 CONTROL BOX COVER CONSULT FACTORY LOUVER, HIGH CAPACITY CONSULT FACTORY...
  • Page 7: Electrical Schematic

    Electrical Schematic OM-ICE CREAM DIPPING CABINET...
  • Page 8: Service Log

    Service Log Model No: Purchased From: Serial No: Location: Date Purchased: Date Installed: Purchase Order No: For Service Call: Date Maintenance Performed Performed By OM-ICE CREAM DIPPING CABINET...
  • Page 9 STOCKAGE TYPE DE POIDS DU MODÈLE LONGUEUR PROFONDEUR HAUTEUR COMPRESSEUR VOLTS AMPS NEMA COUVERCLE NAVIRE (LBS) (GALLONS) DCHFT-45-SR6 45 PO 33 PO 36 PO RETOURNER 5-15P DCHFT-57-SR8 57 PO 33 PO 36 PO RETOURNER 5-15P DCST-36-SR7 36 PO 30 PO...
  • Page 10: Checklist D'installation

    IMPORTANT - À LIRE EN PREMIER - IMPORTANT TUBES DE RÉFRIGÉRANT A PROXIMITE COUVERCLE INTÉRIEUR DE L'ÉVAPORATEUR DANGER CAUTION RISQUE D’INCENDIE OU WARNING ALERTE MISE EN GARDE RISQUE D’EXPLOSION. D’INCENDIE OU INFLAMMABLE D’EXPLOSION EN RAISON RÉFRIGÉRANT UTILISÉ. DO NOT REMOVE PANEL - HIGH VOLTAGE - DE LA PERFORATION DU RISK OF FIRE OR EXPLOSION DUE TO RISK OF FIRE OR EXPLOSION.
  • Page 11: Pieces De Rechange

    DEGRIVAGE MANUEL Il est recommandé que le client contacte l'agent de service agréé local pour lui fournir un devis afin d'effectuer une maintenance préventive périodique. PROCÉDURES MENSUELLES Nettoyer la pale du ventilateur sur l'unité de condensation. LES NETTOYANTS RECOMMANDÉS POUR VOTRE ACIER INOXYDABLE SONT LES SUIVANTS : AGENT DE NETTOYAGE COMMENTAIRES...
  • Page 12: Dépannage

    SERVICE DÉPANNAGE Votre marmite est conçue pour fonctionner de façon silencieuse et efficace lorsque MISE EN GARDE : LES COMPOSANTS DOIVENT ÊTRE REMPLACÉS PAR DES PIÈCES entretenu correctement. Si vous rencontrez des problèmes, voici une liste des vérifications D'ORIGINE. LES TRAVAUX DE MAINTENANCE DOIVENT ÊTRE EFFECTUÉS à...
  • Page 13: Paquet De Réfrigération

    PAQUET DE RÉFRIGÉRATION Liste des pièces APPELEZ L’USINE POUR LES PIÈCES DE RECHANGE : 888-994-7636 DCST-36 / DCST-44 / DCST-54 / ARTICLE PARTIE SERVICE DESCRIPTION DCHFT-45 DCHFT-57 DCFT-36 DCFT-44 DCFT-54 RF CMP1701 COMPRESSEUR, 1/3HP, R290, EMBRACO 115V-60HZ RF CMP1701SC COMPRESSEUR, DÉMARRER LES COMPOSANTS RP CAP1902 BOUCHON, TUBE RF FAN1401...
  • Page 14 BASE Liste des pièces APPELEZ L’USINE POUR LES PIÈCES DE RECHANGE : 888-994-7636 GLISSIERE SUPERIEURE FLIP TOP DCST-36 / DCST-44 / DCST-54 / ARTICLE PARTIE SERVICE DESCRIPTION DCHFT-45 DCHFT-57 DCFT-36 DCFT-44 DCFT-54 RP CNT1925C CONTROLEUR, DANFOSS PRÉPROGRAMMÉ RF CNT1603 THERMISTOR, QTI, CAPTEUR D'AIR, NOIR, 10' RP CVR2001 BOITE DE CONTROLE AVEC PLAQUE DE RECOUVREMENT CONSULTER USINE...
  • Page 15: Schéma Électrique

    Schéma électrique SCHÉMA ÉLECTRIQUE 16FLA(72LRA) 16(10)A 240V~ ARMOIRE A TREMPETTE CONTROL DANFOSS ERC112C SOURCE D’ALIMENTATION 115V-60HZ-1PH 115V CORDON AVEC TOUS FILS 18 AWG BOUCHON A TERRE LIGNES D'ALIMENTATION 120V 50~60hz NEMA # 5-15P NOTE DU CAPTEUR : NEMA NOIR (AIR) = S1 5-15 FICHE VERT...
  • Page 16: Journal D'entretien

    Journal d'entretien No de modèle : Acheté de : No de série : Emplacement : Date d'achat : Date d'installation : No de bon de commande : Pour un appel de service : Date Entretien effectué Effectué par OM-ARMOIRE À TREMPETTE POUR CRÈME GLACÉE...

Table des Matières