Check The Water Parameters; Setting Of The Salt Chlorinator - Pool Technologie Redox Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CHECK THE WATER PARAMETERS

2
At the initial installation of the device or at the beginning of any new season, check and correct necessarily
all the following points :
State of water
A regulated pH
7,0 < pH < 7,4
Stabilizing agent rate
< 35 ppm
Free chlorine rate
> 1.0 ppm
TAC
De 10 à 30°f
TH < 60°f
Be careful : the non compliance with these recommendations will involve inevitably a misuse of the
device which entails the guarantee annulations.
3
SETTING OF THE ENSLAVED SALT CHLORINATOR
Adjust at most of its power, the enslaved salt chlorinator to the redox controller.
Important :
For the protection and longevity of equipments of your pool, it is imperative to respect literally the instructions of use
mentioned in this manual. The presence of an amperometric chlorine regulation, of a redox production controller or a
pH regulation do not exempt from the strict respect of the instructions and do not have authority to eliminate the
risks and damages but only to limit them. Indeed, in spite of the smooth running of a control or regulation device,
other factors may cause damage, in particular :
- an insufficient ventilation in case of covered pool (shelter, tarpaulin, cover)
- a maintenance default of analysis probes (calibration, addition of the consumable...)
- manual processing of supplements excessive or not adapted (choc processing...)
- the non compliance with the instructions of use described in the present user manual
These isolated or organized factors will tend to cause oxidation on all metallic parts and of automatic cover pins and
slats, telescopic shelters and heat exchangers can lead to irreversible deterioration (discoloration) of the pool lining.
Therefore, if the manufacturer's responsibility was engaged for a malfunction of the control or regulation device, it
would be limited to the repair or the replacement of the product free of charge. Then, it is strongly recommended to
check the levels of chlorine and pH each week with your usual analysis kit.
JUSTREGUL UNO - JUSTREGUL DUO - PAPI004083-MULTI1 - FR/EN/ES/DE - Rev.01.19
The pool water must be clear, free from algae or deposits
The pH of the pool must be necessarily regulated and between 7,0 et 7,4. A
wrong pH regulation will entail punctually or sometimes permanently
malfunction of the redox controller.
For an optimal functioning of the redox probe, it is advised to have a stabilizing
agent rate (iso-cyanuric acid) inferior to 35 particles by one million (mg/l).
Water must be already chlorinated with a rate > to 1,0 particle by one million
(mg/l). Make a chlorination shock if necessary.
The TAC (Permanent Hardness) insure the buffer power of the water, it must be
between 10°f to 30°f.
The TH indicates the hardness of water, it means the calcium or magnesium salts
content dissolved in water. The hardness of water should not exceed 60°f.