INSTALLATION
Model RM325H Single-Wheel Blower
VERTICAL DISCHARGE
ROUGH-IN PLATE
MOUNTING
STUDS
1. Mount rough-in plate to mounting studs on inside, top of hood. Use hex nuts
provided. Make sure power cord is at right side of hood.
2. Loosen barrel nuts and wing nut half-way.
3. Lift blower to rough-in plate and over barrel nuts. Slide blower sideward to
engage barrel nuts with small end of keyholes and wing nut with slot.
4. Tighten nuts to secure blower to rough-in plate.
5. Plug rough-in plate power cord and blower power cord into receptacles inside of
hood. DO NOT PLUG POWER CORDS TOGETHER.
HORIZONTAL DISCHARGE
COVER PLATE
MOUNTING
STUDS
BARREL
NUTS
1. Remove cover plate from inside, back of hood and mount it to inside, top of
hood with same hardware. Make sure power cord is at right side of hood.
2. Mount rough-in plate to mounting studs on inside, back of hood. Use hex nuts
provided.
3. Loosen barrel nuts and wing nut half-way.
4. Lift blower to rough-in plate and over barrel nuts. Slide blower sideward to
engage barrel nuts with small end of keyholes and wing nut with slot.
5. Tighten nuts to secure blower to rough-in plate.
6. Plug rough-in plate power cord and blower power cord into receptacles inside of
hood. DO NOT PLUG POWER CORDS TOGETHER.
ROUGH-IN PLATE POWER CORD
(Locate at right side of hood)
MOUNTING
STUDS
BARREL
NUTS
BLOWER
POWER CORD
ROUGH-IN PLATE POWER CORD
(Locate at right side of hood)
MOUNTING
STUDS
ROUGH-IN
PLATE
WING NUT
BLOWER
POWER CORD
INSTALLATION
Model RM326H Dual-Wheel Blower
VERTICAL DISCHARGE
MOUNTING
STUDS
WING
NUT
1. Mount rough-in plate to mounting studs on inside, top of hood. Use hex nuts
provided. Make sure power cord is at right side of hood.
2. Loosen barrel nut half-way.
3. Lift blower to rough-in plate. Slide blower back to engage blower tab with slot in
rough-in plate and slot in blower with barrel nut.
4. Tighten barrel nut to secure blower to rough-in plate.
5. Plug rough-in plate power cord and blower power cord into receptacles inside of
hood. DO NOT PLUG POWER CORDS TOGETHER.
HORIZONTAL DISCHARGE
SLOT
MOUNTING
STUDS
(at bottom-back
1. Remove cover plate from inside, back of hood and mount it to inside, top of
hood with same hardware. Make sure power cord is at right side of hood.
2. Mount rough-in plate to mounting studs on inside, back of hood. Use hex nuts
provided.
3. Loosen barrel nut half-way.
4. Lift blower to rough-in plate. Slide blower down to engage blower tab with slot
in rough-in plate and slot in blower with barrel nut.
5. Tighten barrel nut to secure blower to rough-in plate.
6. Plug rough-in plate power cord and blower power cord into receptacles inside of
3
hood. DO NOT PLUG POWER CORDS TOGETHER.
ROUGH-IN PLATE
SLOT
BARREL NUT
ROUGH-IN PLATE POWER CORD
(Locate at right side of hood)
COVER PLATE
TAB
of blower)
ROUGH-IN PLATE
POWER CORD
(Locate at
right side
of hood)
MOUNTING
STUDS
BLOWER
TAB
BLOWER
POWER
CORD
MOUNTING
STUDS
BLOWER
POWER
CORD
BARREL NUT

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rm326h

Table des Matières