ENGLISH
3.1 - GENERAL
The installation and subsequent maintenance of the solar panel must be performed by the qualified personnel,
in possession of the legal requirements, in compliance with the applicable rules and the technical arrangements
contained in this manual.
The user must keep a valid tax document issued by the seller and proving the date of purchase of the product.
This document must be presented to the authorized technical assistance center staff in case of intervention.
Ensure that periodic checks and maintenance are carried out on the solar panel, and that these interventions are
recorded. In this regard it is suggested to stipulate a maintenance contract.
Keep the booklet and all the documentation related to the product. If the appliance should be sold or transferred
to another owner, or if you move and leave the appliance, always make sure that the manual accompanies the appliance
so that it can be consulted by the new owner and / or installer.
4.1
GENERAL WARNINGS
This appliance must only be used for the purpose for which it was expressly intended. Any other use is to be
considered improper and therefore dangerous.
This device serves to heat water at a temperature lower than the boiling point at atmospheric pressure.
Before connecting the appliance, make a thorough cleaning of all the pipes of the system by professionally
qualified personnel in order to remove any residuals or impurities that could compromise the proper functioning of the
appliance.
ATTENTION: the appliance must be installed by a qualified technician in possession of the technical-
professional requisites according to the law 46/90 which, under his own responsibility, guarantees the respect of the rules
and the rules of the good technique.
4.2
GENERAL HAZARD
For the installation of solar systems, follow the instructions below and refer to all the regulations, laws and
provisions issued by each authority recognized in the field of safety, in the relevant version in force.
The solar system must be installed and used in accordance with recognized technical regulations. Observe the
applicable accident prevention and protection regulations, especially for roof work. See Decree 494 (August 1996) and
D.L. 626 (19 Sept.1994). Observe the accident prevention regulations of the Institute for Insurance against accidents at
work. In general, all must comply with the regulation in force in the place of installation.
Danger of overvoltage: earth the solar circuit for potential equalization and to protect against overvoltage.
Apply pipe clamps to the solar circuit pipes with earthing screws to be connected with a 16 mm2 copper cable to a
potential equalization bar.