Installing MagicSafe
6.5
Installing the ultrasonic sensors
➤ Select a suitable installation location on the left and right A-pillars.
➤ Align the ultrasonic sensors toward the back in the vehicle interior.
6.6
Installing the bonnet contact switch
Installing this switch is only necessary if the vehicle does not already possess
such a switch or if the signal is not available via the CAN bus (see code list).
➤ Find a suitable location in the engine compartment and drill a hole with a
diameter of 8 mm.
➤ During installation ensure that the distance to the closed bonnet is a
minimum of 22 mm and a maximum of 27 mm.
Use putty to check this distance.
You can further reduce the minimum distance by shortening the switch.
➤ Test the switch function after installation.
6.7
Installing the key holder
I
Note
On selecting the installation location, observe the cable lengths.
➤ Selection a suitable installation location in the area of the dashboard.
➤ Drill a hole with a diameter of 15 mm.
➤ Push the sensors into the holders until they lock into place.