Télécharger Imprimer la page

GeneralAire Water Savor GF-WSAVOR Instructions D'installation

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Water Savor™ Controller
Water Savor™ Controller
Installation Instructions
Read and Save These Instructions
Read and Save These Instructions
Read and Save These Instructions
I. Safety
!
WARNING! Improper electrical wiring can result in fi re, failure, or loss of humidity control.
Disconnect electrical power before installing or servicing. Failure to disconnect electrical
power may result in injury or death. All local building and electrical codes must be followed.
Congratulations! You have decided to save money and the environment by installing the Water
Savor™ Controller. The Water Savor™ Controller is an electronic device that controls the amount of
water used by a ow-through by-pass humidi er; part of which would normally be wasted down the
drain.
The Water Savor™ Controller should be installed by a licensed technician. Failure to properly install
or operate the Water Savor™ may result in property damage, personal injury or humidity levels that are less than desired. Read instructions
carefully to safely achieve maximum humidity and water savings.
Safety questions regarding the Water Savor™ Controller may be directed to General Filters, Inc.
CANADIAN CUSTOMERS: (888) 216-9184; USA CUSTOMERS: (866) 476-5101.
II. Application:
When there is a call for humidity, the Water Savor™ Controller cycles 24vac of power to the humidi ers solenoid valve. Settings can be adjusted
1-6 (See Figure 3) to ensure that the humidi er will work at full capacity while also saving the maximum amount of water as possible.
III. Installation Instructions:
Precautions
:
WARNING: Disconnect electrical power before beginning installation. After installation is complete and before leaving, check to ensure the
!
humidi er is functioning as intended.
Mounting:
1.
Chose a location for the Water Savor™. To prevent water damage, mount to the side or above the humidi er (See Figure 1). Never install
below the humidifi er. Some solenoid valve wires are long enough to connect directly to the Water Savor™. If not, additional wire may be
required.
2.
Mount the Water Savor™ on the duct using the (2) #8 X 3/4 PHILLIPS HEX screws provided.
Figure 1
Wiring Instructions
(Wire is not included. 18 gage wire is recommended.)
3.
Connect the two humidi er solenoid wires to the screw terminals labeled: "24VAC TO SOLENOID" (See Figure 2).
4.
Connect the 24VAC power source wires (1 from humidistat & 1 from transformer) to the screw terminals labeled "24VAC IN" (See Figure 2).
IV. Recommended Water Savor™ Dip Switch Settings
1.
Refer to the Recommended Dip Switch Settings Chart (Table; next page) to nd the Water
Savor™ setting that matches the applicable humidi er model.
2.
Use a small at head screw driver to adjust the Water Savor™ to the applicalble setting
(See Figure 3).
1-6 settings (1 = maximum water savings; 6 = minimum water savings).
3.
Only one setting should be ON at a time. (See Figure 3).
NEVER install below the humidifi er.
Mount to the side or above the unit.
Figure 2
:
Canada: GF-WSAVOR
Canada: GF-WSAVOR
USA: GFI #7081
ON POSITION
OFF POSITION
Figure 3

Publicité

loading

Sommaire des Matières pour GeneralAire Water Savor GF-WSAVOR

  • Page 1 Water Savor™ Controller Water Savor™ Controller Canada: GF-WSAVOR Canada: GF-WSAVOR USA: GFI #7081 Installation Instructions Read and Save These Instructions Read and Save These Instructions Read and Save These Instructions I. Safety  WARNING! Improper electrical wiring can result in fi re, failure, or loss of humidity control. Disconnect electrical power before installing or servicing.
  • Page 2 Warranty Registration - Keep a Copy For Your Records  Cut Out to Mail Register Online Warranty Registration www.GeneralAire.com / Support Center Canada: GF-WSAVOR www.cgfproducts.com/Warranty Registration USA: GFI #7081 Product Information Or Mail Serial Number: __________________________________________________...
  • Page 3 Directives d’installation Canada: GF-WSAVOR du contrôle Water Savor USA: GFI #7081 I. SÉCURITÉ: AVERTISSEMENT! Un raccordement électrique inadéquat peut causer un incendie, une panne ou la perte de le contrôle l’humidité. Débrancher l’alimentation électrique avant d’installer le dispositif ou de procéder à...
  • Page 4 FROIDE Modèle Modèle Modèle Modèle Modèle Réglage Réglage Réglage Réglage Réglage Aprilaire Skuttlle Goodman GeneralAire Honeywell White Rogers Lennox Desert Springs SL16 HE220 AA 500 SK 2000 HE12A / 12M 1042 / 1042WSC AA 600 HE240 HE17A / 17M SK 2001...

Ce manuel est également adapté pour:

Water savor gfi 7081