Problem
Automatic ignition does not
spark
Control knobs do not function
If you cannot solve a problem, contact the authorised local Service Centre or Thetford
Customer Service in your country.

12. Servicing

All servicing must be carried out by an approved competent person. Before any service work is
started the appliance should have been left to cool and be disconnected from both the gas and
electrical supplies. After each service the appliance must be checked for gas soundness.
For service, please contact your authorised local Service Centre giving details of the model and
serial number on the data badge plus date of purchase.

13. Putting in storage

Close the gas valve at the gas bottle;
Disconnect the battery;
Ensure that all control knobs are in the 0 position;
Wipe the appliance clean and dry;
Close the glass lids.
Possible cause
Burners are wet or clogged
12V DC battery is discharged
Connections are loose
Ignition points are wet or dirty
Knobs are mounted incorrectly Install knobs correctly
Solution
Dry or clean burners
Charge battery
Secure connections
Dry or clean ignition points