Congratulations on your purchase of this high-quality ESYLUX product. To ensure correct device operation, please
read these installation/operating instructions carefully and keep them in a safe place for future reference.
1 • SAFETY INSTRUCTIONS
CAUTION: work on the 230 V power system must be carried out by authorised personnel only
GB
with due regard to the applicable installation regulations. Switch off the power supply before
installing the system.
μ
= Contact gap < 1.2 mm
Use this product only as intended (as described in the user instructions). Changes or
modifications to the product or painting it will result in loss of warranty. You should check the
device for damage immediately after unpacking it. If there is any damage, you should not
install the device under any circumstances.
If you suspect that safe operation of the device cannot be guaranteed, you should turn the
device off immediately and make sure that it cannot be operated unintentionally.
2 • DESCRIPTION
The OL 100 and OL 200 are ESYLUX lights with in-built, non-replaceable LED lamps.
The AOL 100 and AOL 200 are automatic lights from ESYLUX with in-built, non-replaceable
LED lamps and an integrated 140° motion detector.
ESYLUX motion detectors are passive infrared detectors, which react to moving heat sources
(e.g. people or vehicles). If the motion detector senses a change in thermal radiation inside its
field of detection, depending on the set light value, it will switch on the automatic light for a
preset length of time, as well as additional devices if desired.
Alternatively, the AOL 100 and/or AOL 200 automatic light can be switched off when it gets
light and on when it gets dark. The twilight switch can be used to determine the point at which
this happens.
6
3 • INSTALLATION / ASSEMBLY / CONNECTION
Please observe the following before installing the device:
• Switch off the power supply at the mains before installing the product.
• Any information relating to the motion detector's range is based on an installation height of
1.80 m. (The field of detection will vary depending on the height.)
• To ensure optimum performance (i.e. maximum range), position the device so that people/
vehicles move at an angle to the detector (fig. 1 (1) head-on to the detector (2) diagonally to the
detector).
• Ensure that the detector has a clear line of sight, as infrared beams cannot penetrate solid
objects.
• Take the surrounding area into consideration when installing the device, e.g. neighbouring
plots or the distance to the road.
• The lights should only be installed on a stable, flat surface (e.g. a wall).
The wall base unit and light can be plugged into one another. Disconnect the two components
for installation purposes. Release the locking screw, press in the spring mechanism and remove
the light from the wall base unit (fig. 2.1). Insert the cable and mount the wall base unit as
shown in fig. 3.
Connect the AOL 100 and/or AOL 200 automatic light as shown in circuit diagram fig. 4.
(4.1) Standard operation
(4.2) Standard operation with additional connection of external loads
Connect the OL 100 and/or OL 200 light as shown in circuit diagram fig. 5.
(5.1) Standard operation
(5.2) Controlled by automatic lights, such as AOL 100 and/or AOL 200
Push the light into the wall base unit until you hear the spring mechanism click into place and
secure it with the screw (fig. 2.2).
NOTE: The light must always be mounted so that the luminaire head
faces downwards.