Troubleshooting
SMS 40 has no contact with the GSM net-
work
SMS 40 does not reply to the SMS command and a
symbol for lost connection to G network appears in
heat pump/indoor module menu 4.1.4 (menu 5.3.5 if
your heat pump/indoor module has software version
2041 or earlier).
phone number
Check that the SIM card is correctly installed.
Move the antenna to a better location.
Check that the PIN has been deactivated.
SMS 40 has no contact with the heat
pump/indoor module
The alarm in the heat pump/indoor module display.
See section Disturbances in comfort in the manual
for the heat pump/indoor module.
Incorrectly connected cables between SMS 40 and
heat pump/indoor module.
No reply to the SMS message
The telephone number is not registered in heat
pump/indoor module menu 4.1.4 (menu 5.3.5 if your
heat pump/indoor module has software version 2041
or earlier).
20
sms 4.1.4
alarm receiver

Technical data

Technical specifications

Rated voltage
GSM
(MHz)
Part No.
Dimensions
(mm)
12 VDC 45-80 mA
850/900/1800/1900
067 073
108 x 154 x 39