INSTALLATION · MANUAL
4. Anschlussbelegung · Wiring Diagram · Raccordement · 5.0600.65.60
2/2
ACHTUNG: Anschluss der Netzteile muss stromlos erfolgen, da sonst Entladungen im Netzteil zur
Schädigung der LED führen können. Es darf keine Primärspannung anliegen.
HINWEIS: Die Installation eines bauseitigen Überspannungsschutzes
nach DIN VDE 0100-443, DIN VDE 0100-534 und EN 62305 wird empfohlen.
HINWEIS: Nicht geeignet für Konstantstrom-Scheinwerfer (350 mA Versionen)!
ATTENTION: The power supply must be connected without power, since otherwise discharges in the
power supply unit may damage the LED. Primary voltage must not be present.
NOTE: Installation of customised surge protection in accordance with DIN VDE 0100-443,
DIN VDE 0100-534 and EN 62305 is recommended.
NOTE: Not suitable for constant current lights (350 mA versions)!
ATTENTION: Les blocs d'alimentation doivent être raccordés hors tension, sinon des décharges dans le bloc
d'alimentation peuvent détériorer les LED. Aucune tension primaire ne doit être présente.
REMARQUE: L'installation d'un système anti-surtension local conforme aux normes DIN VDE 0100-443,
DIN VDE 0100-534 et EN 62305 est recommandée.
REMARQUE: Ne convient pas pour projecteurs de courant constant (versions 350 mA)!
Important information (If the following points are disregarded, the guarantee expires.)
• Before installation, all parts must be checked for transport damage!
• All fitting, installation and electrical work must be performed by qualified specialist staff.
• Only use stainless steel tools to avoid external rust!
• The cable length of the lights should be chosen in such a way that it is not necessary to extend in water or moist environments. Later complaints resulting from this
cannot be accepted.
• Only original Wibre operating units may be used.
• An installation distance of 10 cm between operating devices is urgently recommended in order to avoid mutual heating up.
• The operating devices must be connected without power, as otherwise discharges in the power supply may cause the LED to be damaged. No primary voltage may be
applied when changing the LED.
• Note polarity when changing the lights! The wrong polarity can damage the LED module.
• It is recommended that the customer install an overvoltage protection in accordance with DIN VDE 0100-443, DIN VDE 0100-534 and EN 62305.
• Please comply with all anti-ESD (electrostatic discharge) measures during all work on the spotlight, operating device and LED.