Connections
Line connection
(5-Position screw-terminal)
Direction
Connection
Receiver
Receiver
Transmitter
Transmitter
The definations R+/R–, T+/T– can be various between
different manufactures.
Terminal connection (DCE)
(RS-232-C/V.24, 25-Position D-sub, female)
Direction
I
O
I
O
O
O
I = Input O = Output on MA-45
12
ITU-T V.11
no.
Description
1
A' (R+)
2
B' (R-)
3
A (T+)
4
B (T-)
5
Shield
Connection
2
3
4
5
6
7
8
ITU-T V.24
Signal name
Code
103
TD/Transmitted data
104
RD/Received Data
105
RTS/Request To Send
106
CTS/Clear To Send
107
DSR/Data Set Ready
102
SG/Signal Ground
109
DCD/Data Carrier Detect
6045-2001