Minimum Gage of Extension Cords
Ampere
Rating
Volts
8-13 A
120 V
4-6.5 A
220 V
Do not abuse extension cord and do not yank on any cord disconnect. Keep cord
away from heat and sharp edges. Always disconnect the extension cord from the
receptacle before disconnecting the product from the extension cord.
WARNING: To reduce the risk of electrocution, keep all connections dry and off
the ground. Do not touch plug with wet hands.
THE REAM-A-MATIC – HOW IT WORKS
The Ream-A-Matic uses a flexible shaft, which is available in different lengths
and diameters to fit the size of the tube to be cleaned. As the shaft rotates
inside its watertight nylon casing, the unit feeds water through the casing to the
cleaning tool. While the operator feeds the rotating shaft assembly through the
tube, the water flow flushes out deposits as they are loosened. A solenoid valve
automatically activates the water flow only when the machine is running.
Three models of the Ream-A-Matic are described in this manual: RAM-4,
RAM-4X and RAM-PTC.
The RAM-4 with a
/
"-1" (6.4-25.4mm) I.D. It is a compact, self-contained, roll-anywhere unit which
1
4
permits operation in tight quarters.
The RAM-4X is a heavy-duty version of the RAM-4, equipped with a 1 HP
(0.75 kW) electric motor, it is designed for cleaning tubes over 1" (25.4mm) I.D.
It requires a
/
" (12.7mm) heavy-duty flexible shaft. The RAM-4X can also be
1
2
used for dry applications.
The RAM-PTC Port-A-Ram is a lightweight Ream-A-Matic machine that can
be hand carried, making it ideal for personnel who will use the equipment in
multiple locations. It operates essentially the same as the RAM-4 and performs
the same job. The Port-A-Ram is direct drive so it rotates the cleaning tool at
1,700 rpm.
ASSEMBLY – RAM-4 AND RAM-4X
1. Place the Ream-A-Matic machine on bench or floor with the front
louvered side down.
0-25' (0-7.6m) 26'-50' (7.9-15.3m) 51'-100' (15.6-30.5m) 101'-150' (30.8-45.8m)
18
18
/
HP (0.4 kW) motor is designed for cleaning tubes and pipes
1
2
16
14
18
18