Oil Sensor; Stopping The Generator; Troublshooting; Troubleshooting Chart - BE BE3500PS Manuel D'utilisation

Table des Matières

Publicité

STOPPING THE GENERATOR

Stopping The Generator
1. Turn off the power switch of the electric equipment and unplug the
cord from receptacle of the generator.
2. Allow the engine about 3 minutes to cool down without load before
stopping.
3. Push the engine switch to the OFF position.
4. Push the main switch to the OFF position.

OIL SENSOR

The oil sensor detects a drop in oil level in the crankcase and
automatically stops the engine when the oil level drops below a
predetermined level.
When the engine has stopped automatically, turn off the generator, and
check the oil level. Refill engine oil to the upper level as instructed and
restart the engine.
CAUTION
DO NOT remove oil sensor probe when refilling with oil.
Remove oil filler cap on the opposite side of carburetor.
22

TROUBLESHOOTING

Troublshooting

TROUBLESHOOTING CHART

If you are experiencing a problem that is not listed in this chart, or have
checked all the possible cause listed and you are still experiencing the
problem, see your authorized dealer.
Problem
Cause
Engine will not start
1. Check if engine switch is off.
2. Fuel Tank empty.
3. Check to make sure generator is not
connected to an appliance.
4. Check spark plug for loose spark plug cap
5. Check spark plug for contamination.
6. Check engine oil level.
Generator has no output
1. Check if the DC circuit breaker is turned off.
2. Check AC receptacle and DC terminals for
loose connection.
3. Check to see if engine starting was
attempted with appliances already
connected to generator.
Correction
1. Turn engine switch to the Choke position.
2. Fill tank ensuring you do not overfill.
3. If connected, turn off the power switch on
the connected appliance and unplug.
4. If loose, push spark plug cap back into place
5. Remove spark plug and clean electrode.
6. If engine oil level is low, add oil as per
instructions.
1. Depress or flip the circuit breaker into ON
position.
2. Secure connection if necessary.
3. Turn off switch on the appliance, and
disconnect cable from receptacle.
Reconnect after generator has been started
properly.