Lennox CLIMATIC 60 Manuel D'utilisation page 53

Masquer les pouces Voir aussi pour CLIMATIC 60:
Table des Matières

Publicité

CLIMATIC™ 60 – REFROIDISSEURS DE LIQUIDE A CONDENSATION PAR AIR
Level 1
Item
Level 2 Item
User
Water
User
Water
User
Water
User
2300
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
User
Pump
MUL41F-0610/06-2011
Level 3 Item
Level 4 Item
2250
Custom
2251
Sp 4/20mA
Custom
2252
Sp +/-0.5°C
Custom
2253
2nd Sp
2310
Cooling P1
2311
Status
Cooling P1
2312
Sw State
Cooling P1
2313
Output
Cooling P1
2314
Hour
Cooling P1
2315
Flow
2320
Cooling P2
2321
Status
Cooling P2
2322
Sw State
Cooling P2
2323
Output
Cooling P2
2324
Hour
Cooling P2
2325
Flow
2330
Heating P1
2331
Status
Heating P1
2332
Sw State
Heating P1
2333
Output
Heating P1
2334
Hour
Heating P1
2335
Flow
2340
Heating P2
2341
Status
Heating P2
2342
Sw State
Heating P2
2343
Output
Heating P2
2344
Hour
Heating P2
2345
Flow
2350
Cooling Flow
2351
T.In
Cooling Flow
2352
T.Out
Cooling Flow
2353
P.In
Cooling Flow
2354
P.Out
Cooling Flow
2355
Delta dT
Cooling Flow
2356
Delta dP
Cooling Flow
2357
Capacity
Cooling Flow
2358
Flow
Cooling Flow
2359
Flow
R/W/Z
Unit
Min
Std
R
°C
4,0
R
°C
-0,5
R
*
0
R
*
*
R
*
0
R
*
0
R
HH
0
R
*
0,0
R
*
*
R
*
0
R
*
0
R
HH
0
R
*
0,0
R
*
*
R
*
0
R
*
0
R
HH
0
R
*
0,0
R
*
*
R
*
0
R
*
0
R
HH
0
R
*
0,0
R
°C
-50,0
R
°C
-50,0
R
Bar
0,0
R
Bar
0,0
R
°C
0,0
R
Bar
0,0
R
%
0,0
R
m3
0,0
R
*
0
Max
Description
*
20,0
External evaporator set point
External offset evaporator set
*
0,5
point
*
1
Second set point switch status
*
*
Evaporator pump 1 status
*
1
Evaporator pump 1 input
*
1
Evaporator pump 1 output
*
99999
Evaporator pump 1 output
*
100,0
Evaporator flow switch
*
*
Evaporator pump 2 status
*
1
Evaporator pump 2 input
*
1
Evaporator pump 2 output
*
99999
Evaporator pump 2 output
*
100,0
Evaporator flow switch
*
*
Condenser pump 1 status
*
1
Condenser pump 1 input
*
1
Condenser pump 1 output
*
99999
Condenser pump 1 output
*
100,0
Condenser flow switch
*
*
Condenser pump 2 status
*
1
Condenser pump 2 input
*
1
Condenser pump 2 output
*
99999
Condenser pump 2 output
*
100,0
Condenser flow switch
*
105,0
Evaporator T° inlet
*
105,0
Evaporator T° outlet
*
6,0
Evaporator pressure in
*
6,0
Evaporator pressure out
*
20,0
Evaporator delta T°
*
6,0
Evaporator delta pressure
*
100,0
Evaporator flow capacity
*
100,0
Evaporator flow meter
*
1
Evaporator flow switch
Page 51

Publicité

Table des Matières
loading

Table des Matières