DENIA DF-70 Instructions D'utilisation Et D'entretien page 5

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
INSTALLATION
- The lower part of the fireplace needs to have a direct air entrance, from the inside or
outside, with a size of at least 450 cm
- It is recommended to install a vent in the area between the roof and the top of the fire-
place, isolating all areas close (to improve the sealing), in order to exploit the heat of
convection. To do so leave a minimum spacing of 50 mm around the fireplace to create
the convection chamber.
- Before installing the fireplace it ' s recommended to take out all its loose interior parts
to avoid breakage, and once placed at its final site reinstall all the interior parts.
- Once positioned, perform a functional test before final embedment. It ' s recommended
to embed the fireplace from the bottom upwards.
- The masonry must not touch the upper part of the fireplace, allow a minimum of 5mm.
space to prevent the the creation of fissures in the upper wall due to expansion of the metal.
FUEL
- Use only dry wood with a maximum moisture content of 20%. Wood with a moisture
content higher than 50 or 60% does not heat and combusts very badly, and creates
a lot of tar, releases excessive amounts of vapour and deposits excess sediments onto
the device, glass and smoke outlet.
- The fire should be lit using special fire lighters, or paper and small pieces of wood.
Never try to light the fire using alcohol or similar products.
- Do not burn domestic rubbish, plastic materials or greasy products that can pollute
the environment and lead to risks of fire due to obstruction of the pipes.
FUNCTION
- It is normal for smoke to appear during the first few uses of the fireplace, as certain
components of the heat-resistant paint burn whilst the pigment of the actual device is
fixed. Therefore the room should be aired until the smoke disappears.
- The device is not designed to function with the door open under any circunstances.
- The device is intended to function intermitently with intervals for recharging the fuel.
- For the lighting process of the device it is recommended you use paper, fire lighters or
small sticks of wood. Once the fire starts to burn, add two logs of wood each
weighing 1 to 1'3 Kg. as a first initial charge. In this lighting process the air inlets of the
device must be kept completely open. Once the fire is more intense, close the door
completely (if open) and regulate the intensity of the fire by closing and opening the
air inlets.
- In order to achieve the stated nominal heat output of this device a total quantity of 1.7Kg.
of wood (roughly two logs weighing 1 Kg. each) must be placed inside at intervals of
one hour. In any instance a charge of fuel must not be added to the device until the
previous charge has been burnt, leaving only a basic fire bed which is enough to light
the next charge but no stronger.
- It is normal for the seal of the glass door panel to melt with use. Even though the device
can function without this seal, it is recommended that you replace it seasonally.
2
5
Mod.
D F - 7 0

Publicité

Table des Matières
loading

Table des Matières