Abnormal vibration
F
G
G
Leaks
G
 Druckluftanlagenbau GmbH
RIC M30S – M120S
RIC M70RD – M120D
residues, etc.).
Worn bearing.
Unit installation position unsuitable.
The impeller is damaged.
The impeller has accumulated deposits.
Unit fixed without vibration dampers.
Rigid connection to the system
Faulty bearing on blower side or motor side.
Faulty gaskets on the silencer.
Faulty gaskets on the cover.
Tel. +49 ( 0 ) 2151 9931 99 -
Have the bearing replaced by RICO After-Sales Service.
Have the units installed on structures that cannot transmit
or amplify the noise (tanks, metal plates, etc.) by the
Technician.
Have the impeller replaced by RICO After-Sales Service.
Have the unit cleaned inside by RICO After-Sales Service.
Have the unit secured with vibration dampers by the
Technician.
Have flexible sleeves installed between the unit and the
pipes by the Technician.
Have the bearing replaced by RICO After-Sales Service.
Have the gaskets checked and, if necessary, replaced by
RICO After-Sales
Service.
Have the gaskets checked and, if necessary, replaced by
RICO After-Sales
Service.