FOUTCODE
H9
THERMISTOR LUCHT BUITENSHUIS KORTSLUITING/OPEN
J1
FOUT DRUKSENSOR
J3
COMPRESSOR AFVOERLEIDING THERMISTOR KORTSLUITING/OPEN/VERKEERD GEPLAATST
J5
AANZUIGLEIDING THERMISTOR KORTSLUITING/OPEN
J6
WARMTEWISSELAAR BUITENSHUIS THERMISTOR KORTSLUITING/OPEN
J7
SUBKOELING WARMTEWISSELAAR THERMISTOR KORTSLUITING/OPEN
J8
VLOEISTOFLEIDING THERMISTOR KORTSLUITING/OPEN
J9
GASLEIDING THERMISTOR KORTSLUITING/OPEN
L1
PCB-FOUT INVERTER BUITENSHUIS
L3
OVERVERHITTING REGELKAST BUITENSHUIS
L4
OVERVERHITTING KOELLICHAAM
L5
IPM-FOUT/IGBT-FOUT
L8
INVERTER COMPRESSOR TE HOGE STROOMSTERKTE
L9
PREVENTIE TE HOGE STROOMSTERKTE COMPRESSOR
LC
COMMUNICATIEFOUT (REGEL-PCB EN INVERTER-PCB BUITENSHUIS)
P1
OPEN FASE OF SPANNINGSONBALANS
P4
KOELLICHAAM THERMISTOR KORTSLUITING/OPEN
PJ
FOUT INSTELLING CAPACITEIT
U0
ONVOLDOENDE GAS
U2
GELIJKSTROOM BUITEN BEREIK
U4
COMMUNICATIEFOUT
U7
COMMUNICATIEFOUT (REGEL-PCB EN IPM-PCB BUITENSHUIS)
UA
INSTALLATIEFOUT
UF
ONJUISTE COMBINATIE INSTALLATIE LEIDING & BEDRADING /VERKEERDE BEDRADING/
ONVOLDOENDE GAS
UH
ANTIVRIES (OVERIGE VERTREKKEN)
OPMERKING
1.
Een kort akoestisch signaal en twee achtereenvolgende akoestische signalen zijn een aanduiding
van niet-bij-elkaar-horende codes.
2.
U kunt de weergave van code annuleren door de toets AAN-TIMER ANNULEREN of UIT-TIMER
ANNULEREN 5 seconden ingedrukt te houden. De codeweergave wordt vanzelf geannuleerd als
de knop 1 minuut lang niet wordt ingedrukt.
BETEKENIS