6 Warnings
6.1 Flashing display
The display will flash if the temperature in the aquarium deviates from
the set value by more than + 3 or – 3 °C.
Check immediately:
• Are the heating systems working correctly?
• Is the temperature sensor secured correctly?

7 Comfort functions

7.1 Dimming the display

The display and all LEDs can be dimmed to adapt them perfectly to
the ambient light conditions:
• Press "Dimmer" key and set the desired brightness with "+" and "–".
• If the keys remain unused for 3 sec., this value will be adopted.
Possible dimming levels: 1-8
7.2 Keypad lock (child-proof safety lock)
The keypad lock prevents unintentional alteration of the programmed
settings:
• To activate the keypad lock: Press "Dimmer" and "°C" keys simulta-
neously, "Keypad lock" LED lights up.
• To deactivate the keypad lock: Press key combination again, LED
goes off
Note: If any key is pressed while the keypad lock is active, "SAF" (for
SAFE) will appear on the display. The only available function is
display of the set temperature via the appropriate keys.
22
8 What if ... Troubleshooting
8.3 Possible causes of faults
Fault
Set temperature is
not reached
Heating system not
working, although
indicator lamp ON
Display reads
"F01 - F04"
DENNERLE
Duomat Evolution

8.1 Replacing the fuses

If one of the connected heating system fails to work although the cor-
responding LED indicates that it is on, either the heating system or the
fuse is defective.
• Checking the fuse: Connect standard table lamp to the socket on
the power unit. Set required temperature sufficiently high for the
heating system to be activated. If the lamp does not light up, the
fuse is defective.
• Replacing the fuse: Disconnect the Duomat from the mains.
Unscrew fuse holder and remove defective fuse. Fit new fuse of
the same type (from electrical retailer) and screw fuse holder
back into place.
8.2 What will happen in case of a power failure?
In case of a power failure, all programmed settings and functions will
be retained in the internal permanent memory. As soon as the power
supply to the Duomat is resumed, it will automatically perform the
necessary control actions to restore the temperature in the aquarium
to the set value.
Cause
Remedy
Adjustable heater set too low
Set required temperature higher on
adjustable heater
Capacity of adjustable heater too
Use adjustable heater with higher
low
heating capacity
Temperature sensor positioned
Secure temperature sensor at spot
incorrectly
where the water movement is good
Fix sensor back correctly
Sensor has slipped out
of aquarium
in position
Heating system defective
Check heating system, replace if
necessary
Fuse defective
Replace fuse, see 8.1
Temperature sensor or Duomat
Send Duomat in to DENNERLE
defective
after-sales service for inspection.