Appropriate Use; Technical Specifications; Installation Instructions - Electrotechnik schabus GX-B2 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12

APPROPRIATE USE

The GAS ALARM GX-B2 with external sensor is a gas warning device for city, natural and
liquefied gases and can already deliver a warning at a gas concentration that lies well below
life-threatening values. This monitoring system is, therefore, in line with its purpose, set to a
very high sensitivity (see table TECHNICAL DATA). The alarm is signalled acoustically and
optically. The unit is suitable for normal household use and may not be used in areas at risk
of explosion.
Another use of the device as described above is not authorized.

TECHNICAL SPECIFICATIONS

Operating voltage:
Power consumption:
Humidity (ambient):
Operating temperature:
Protection type:
Acoustic pressure sounder:
Cable length:
Dimensions (HxWxD):
Data diagram Sensor
Gas type
CO
Methane
Propane (isobutane)
Ethanol (acetone)

INSTALLATION INSTRUCTIONS

The GAS ALARM GX-B2 and the sensor may be installed
must be correctly placed according to the type of gas to ensure faultless operation of the
alarm system.
It is essential to observe the prescribed sensor mounting height!
For your own safety and reassurance, please obtain information from your
supplier regarding their gas type and its properties!
8
230 (+/-10%) V AC / 50-60 Hz
approx. 3 W
5–90 % RH (non-condensing)
0 °C / +40 °C
IP 20
90 dB @ 10 cm
2.5 m
118x60x44 mm
Trigger point acc. to diagram
no alarm triggered
2500ppm (0.25%)
1000ppm (0.1%)
2500ppm (0.25%)
Minimum concentration
no alarm triggered
<0.5%
<0.2%
<0.5%
only

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

300226

Table des Matières