CONVERSION INSTRUCTIONS
11. Attach the quick connect socket to the natural gas source.
Natural Gas Hose
To Fireplace
12. After installing the conversion kit, verify that the components are still correctly positioned
(see diagram below).
Thermocouple
Make sure the flame
is contacting the
thermocouple.
Shut-O
Quick Connect Socket
NOTE: Igniter housing removed for example only.
Natural Gas Source
Valve
Note: Use 1/2" or 3/8" NPT. See
"Parts List" page for correct size.
9
Igniter Pin
You should see the
igniter pin spark
when pushing the
igniter button.