Series – Parallel Connection of Batteries
Solar Charge Controller
SCC-30AB (rear view)
Figure 9.3 above shows a series – parallel connection consisting of four 6 V, 200 Ah batteries to form a 12 V,
400 Ah battery bank. Two 6 V, 200 Ah batteries, Batteries 1 and 2 are connected in series to form a 12 V, 200 Ah
battery (String 1). Similarly, two 6 V, 200 Ah batteries, Batteries 3 and 4 are connected in series to form a 12 V,
200 Ah battery (String 2). These two 12 V, 200 Ah Strings 1 and 2 are connected in parallel to form a 12 V, 400
Ah bank.
!
CAUTION!
When 2 or more batteries / battery strings are connected in parallel and are then connected to the Solar
Charge Controller (See Figs. 9.2 and 9.3 given above), attention should be paid to the manner in which the
Solar Charge Controller is connected to the battery bank. Please ensure that if the Positive output cable of the
Solar Charge Controller (Cable "A") is connected to the Positive battery post of the first battery (Battery 1 in
Fig. 9.2) or to the Positive battery post of the first battery string (Battery 1 of String 1 in Fig. 9.3), then the
Negative output cable of the Solar Charge Controller (Cable "B") should be connected to the Negative battery
post of the last battery (Battery 4 as in Fig. 9.2) or to the Negative Post of the last battery string (Battery 4 of
Battery String 2 as in Fig. 9.3). This connection ensures the following:
The resistances of the interconnecting cables will be balanced.
All the individual batteries / battery strings will see the same series resistance.
All the individual batteries will charge at the same charging current and thus,
will be charged to the same state at the same time.
None of the batteries will see an overcharge condition.
If the Positive output cable of the
the first battery (Battery 1 in Fig. 9.2) or to the Positive battery post of the first battery string (Battery 1 of String 1
in Fig. 9.3), and the Negative output cable of the battery charger (Cable "B") is connected to the Negative battery
post of the first battery (Battery 1 as in Fig. 9.2) or to the Negative Post of the first battery string (Battery 1 of Battery
String 1 as in Fig. 9.3), the following abnormal conditions will result:
The resistances of the connecting cables will not be balanced.
The individual batteries will see different series resistances.
All the individual batteries will be charged at different charging current and thus,
will reach fully charged state at different times.
The battery with lower series resistance will take shorter time to charge as compared to the battery which
sees higher series resistance and hence, will experience over charging and its life will be reduced.
18
Cable "B"
Cable "A"
Battery 1
PV +
Typical Battery Connections
PV -
BAT +
12V Battery
BAT -
Cable "B"
Battery 1
Cable "A"
PV +
PV -
BAT +
6V Battery
BAT -
Cable "B"
Fig. 9.3: Series-Parallel Connection
Solar Charge Controller
Battery 2
Battery 3
12V Battery
12V Battery
String 1
Battery 2
Battery 3
6V Battery
6V Battery
(Cable "A") is connected to the Positive battery post of
Battery 4
12V Battery
String 2
Battery 4
6V Battery

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour Samlex America SSP-100-KIT

Ce manuel est également adapté pour:

Ssp-150-kitSsp-200-kit

Table des Matières