Important information

Intended use

The mounting instructions come as part of the Duravit
shower trays and must be read carefully prior to
installation.
Target readership and qualifications
The shower trays must only be installed by trained
plumbing engineers.

Explanation of the symbols

Link to the mounting instructions in this section
Link to other instructions
Inspection (e.g. for scratches)
Indication of the length of time (e.g. 10 minutes)
Inspect to check for leaks and leak-tightness
>
Action required

Safety instructions

Product and / or property damage
A breach of local and country-specific regulations and
standards can cause damage to the product
and/or property damage.
> Observe the local installation regulations and any
country-specific standards at all times.

Mounting instructions

Please read pre-installation information sheets prior to
the installation. These are available to download on the
Internet at www.duravit.com.
A2
B2
C2
Using the sealing set
> Use the optional sealing set # 792803 to install
DuraSolid shower trays flush with the floor
depending on the position of the installation and
the site conditions.
> Observe the separate instructions for mounting
the sealing set.
Version A
A10 A17
Using silicone without acetic acid
> Use alkoxy-based silicone.
Version B
B3
Installing the shower tray flush with the floor
> Observe the installation heights of the individual
products (a+b) and the height of the adhesive layer
(z) to install the shower tray flush with the floor.
B17
Using the wall profile
> Use the optional rubber profile # 790104 for noise
reduction and to accommodate expansions in the
screed depending on the position of the installation
and the site conditions.
B14 B20 B25
Using silicone without acetic acid
> Use alkoxy-based silicone.
Variant C
C3
Using the noise reduction gasket
> Mount the noise reduction gasket # 791372 in
order to meet the higher requirements for noise
reduction in accordance with DIN 4109/VDI 4100/
SIA 181.
> Observe the separate instructions for mounting the
noise reduction gasket.
C4
Installing the shower tray flush with the floor
> Measure the depth of the niche (x) in order to
install the shower tray flush with the floor.
C5
Setting the support frame height
> Preset the height of the support frame (c) via the
feet, according to the depth of the niche (x) and the
height of the shower tray (a): c = x - a
C20
Using silicone without acetic acid
> Use alkoxy-based silicone.
5