Zennio KLIC-MITT v2 Manuel D'utilisation page 35

Table des Matières

Publicité

1 bit
22
1 bit
23
1 bit
1 byte
1 byte
24
1 byte
1 byte
1 byte
1 byte
25
1 byte
1 byte
26
2 Bytes
27
2 Bytes
28
1 bit
29
1 bit
30
2 Bytes
31
4 Bytes
32
2 Bytes
33
1 bit
34
1 bit
35
1 bit
36
1 bit
37
14 Bytes
http://www.zennio.fr
S
C T R - -
DPT_Switch
S
C T R - -
DPT_Switch
E
C - - W -
DPT_Step
E
C - - W -
DPT_Scaling
E
C - - W -
DPT_Scaling
E
C - - W -
DPT_Scaling
E
C - - W -
DPT_Scaling
S
C T R - -
DPT_Scaling
S
C T R - -
DPT_Scaling
S
C T R - -
DPT_Scaling
S
C T R - -
DPT_Scaling
S
C T R - -
DPT_Value_Temp
E
C - - W -
DPT_Value_Temp
E
C - - W -
DPT_Switch
S
C T R - -
DPT_State
E
C - - W -
DPT_TimePeriodSec
E/S
C T R W -
DPT_LongDeltaTimeSec
E/S
C T R W -
DPT_TimePeriodHrs
S
C T R - -
DPT_Alarm
S
C T R - -
DPT_Alarm
S
C T R - -
DPT_Alarm
S
C T R - -
DPT_Alarm
S
C T R - -
DPT_String_ASCII
Support technique
0/1
[AC] Lamelles horizontales (état)
0/1
[AC] Lamelles horizontales (état)
0/1
[Climat] Lamelles: Contrôle par Pas
0 % - 100 %
[AC] Lamelles: contrôle en pourcentage:
0 % - 100 %
[AC] Lamelles: contrôle en pourcentage:
0 % - 100 %
[AC] Lamelles: contrôle en pourcentage:
0 % - 100 %
[AC] Lamelles: contrôle en pourcentage:
[Climat] Lamelles: contrôle pourcentage
0 % - 100 %
(état)
[Climat] Lamelles: contrôle pourcentage
0 % - 100 %
(état)
[Climat] Lamelles: contrôle pourcentage
0 % - 100 %
(état)
[Climat] Lamelles: contrôle pourcentage
0 % - 100 %
(état)
[Climat] Température mesurée pour le
-273,00° - 670760,00°
climat
-273,00° - 670760,00°
[AC] Température de référence externe: [0 ... 70] ºC
0/1
[AC] Off automatique
0/1
[AC] Off automatique (état)
0 - 65535
[AC] Retard d'extinction automatique
-2147483648, 2147483647
[AC] Temps d'opération (s)
0 - 65535
[AC] Temps d'opération (h)
0/1
[AC] Erreur interne: communication
0/1
[AC] Erreur interne: temps dépassé
[AC] Erreur interne: accusé de réception
0/1
erroné
[AC] Erreur de l'unité d'AC: erreur
0/1
active
[AC] Erreur unité AC: code d'erreur
http://support.zennio.fr
KLIC-MITT v2
0 = Automatique On; 1 = Automatique
Off
0 = Automatique Off; 1 = Automatique
On
0=Moins Fort: 1=Plus Fort
[0]% = Mov.; [0.4...25.1]% = P1;
[25.5...50.2]% = P2; [50.6...75.3]% =
P3; [75.5...100]% = P4
[0.4...25.1]% = P1; [25.5...50.2]% =
P2; [50.6...75.3]% = P3;
[75.5...100]% = P4
[0]% = Mouv.; [0.39...20]% = P1;
[20.39...40]% = P2; [40.39...60]% =
P3; [60.39...80]%= P4;
[80.39...100]% = P5
[0.39...20]% = P1; [20.39...40]% =
P2; [40.39...60]% = P3;
[60.39...80]%= P4; [80.39...100]%=
P5
Mouv. = 0%; P1 = 25.1%; P2 =
50.2%; P3 = 75.3%; P4 = 100%
P1 = 25.1%; P2 = 50.2%; P3 =
75.3%; P4 = 100%
Mouv. = 0%; P1 = 20%; P2 = 40%; P3
= 60%; P4 = 80%; P5 = 100%
P1 = 20%; P2 = 40%; P3 = 60%; P4 =
80%; P5 = 100%
Température de la sonde interne (ºC)
0 = Désactiver; 1 = Activer
0 = Inactif; 1 = Actif
[0 ... 3600 s (0 = Désactivé)
Temps en secondes
Temps en heures
Incapable d'établir communication avec
l'AC
Pas de réponser eçue de l'A/C
Accusé de réception reçu avec erreurs
Erreur dans l'unité de AC
Voir le manuel de l'unité d'AC