Technical Data; Accuracy; Ambient Conditions; Supply Voltage (External) - Balluff PROFINET BTL7-V50T-M -P-C003 Notice D'utilisation

Capteur de déplacement micropulse en boîtier profilé
Masquer les pouces Voir aussi pour PROFINET BTL7-V50T-M -P-C003:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BTL7-V50T-M _ _ _ _ -P-C003
Micropulse Transducer in a Profile Housing
6

Technical data

6.1

Accuracy

The specifications are typical values for BTL7-V50T... at
24 V DC and room temperature, with a nominal length of
500 mm in conjunction with the BTL5-P-3800-2,
BTL5-P-4500-1, BTL5-P-5500-2
BTL6-A-3801-2
, BTL5-F-2814-1S, BTL5-T-2814-1S,
1)
BTL5-M-2814-1S or BTL5-N-2814-1S.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Position resolution
Non-linearity with a constant distance
between the magnet and profile:
Nominal length ≤ 5500 mm
Nominal length > 5500 mm
Hysteresis
Repeat accuracy
Temperature coefficient
2)
Velocity resolution
Min. detectable velocity
Max. detectable velocity
6.2

Ambient conditions

Operating temperature
Storage temperature
Relative humidity
Shock rating
per EN 60068-2-27
4)
Continuous shock
per EN 60068-2-29
4)
Vibration
per EN 60068-2-6
4)
Degree of protection per
IEC 60529
Connector C003 (when
attached)
12
english
, BTL6-A-3800-2
,
1)
1)
1 µm
±30 µm
±0.02 % FS
≤ ±10 µm
≤ ±5 µm
(typ. ±2.5 µm)
≤ 18 ppm/K
0.1 mm/s
1 mm/s
10 m/s
3)
−40°C to +85°C
−40°C to +100°C
< 90%, non-condensing
150 g/6 ms
150 g/2 ms
20 g, 10 to 2000 Hz
IP 67
6.3

Supply voltage (external)

Voltage, stabilized
5)
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
6.4

Output

Short-circuit resistance
6.5

Dimensions, weights

Housing height
Nominal length
Weight (depends on length)
Housing material
6.6

Maximum sampling rate f

At nominal length
0050 to 0250 mm
0251 to 0600 mm
0601 to 1300 mm
1301 to 2700 mm
2701 to 5500 mm
5501 to 7600 mm
> 7601 mm
In the position range 0 to 20 mm, the specified linearity limit can be
1)
exceeded by ±100 µm.
Nominal length = 500 mm, magnet in the middle of the measuring range
2)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
3)
level.
Individual specifications as per Balluff factory standard
4)
For
: The transducer must be externally connected via a limited-
5)
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
10 to 30 V DC
≤ 0.5 V
SS
≤ 120 mA up to 1524 mm
≤ 160 mA from 1525 mm
≤ 500 mA/10 ms
Up to 36 V
Up to 36 V
500 V AC
Signal cable to GND
36.8 mm
50 to 7620 mm
Approx. 1.4 kg/m
Anodized aluminum
max
780 Hz
710 Hz
600 Hz
460 Hz
245 Hz
180 Hz
170 Hz

Publicité

Table des Matières
loading

Table des Matières