Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Installationsanleitung Analog Module
Installation Instructions Analogue module
Notice d'installation Modules analogiques
(Factory option)
KERN KFB-A04-A05
Version 1.0
2019-02
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Tel: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
KFB-A04-A05-IA-def-1910

Publicité

Table des Matières
loading

Sommaire des Matières pour KERN and SOHN KFB-A04

  • Page 1 KERN & Sohn GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@kern-sohn.com Internet: www.kern-sohn.com Installationsanleitung Analog Module Installation Instructions Analogue module Notice d'installation Modules analogiques (Factory option) KERN KFB-A04-A05 Version 1.0 2019-02 KFB-A04-A05-IA-def-1910...
  • Page 3: Table Des Matières

    KERN KFB-A04-A05 Version 1.0 2019-02 Installationsanleitung Analog-Module Inhaltsverzeichnis Allgemeines ....................3 Montage des Moduls ......................3 Prüfen der Anschlüsse ......................5 1.2.1 Ohne Last: ..........................5 1.2.2 Mit Max-Last: .......................... 5 KFB-A04-A05-IA-d-1910...
  • Page 4: Allgemeines

    Anschluß an folgende KERN-Modelle möglich: • KFB-TAM • UFB • UFA • IFB • NFB • BFB KFB-A04 KFB-A05 0 – 10 V 4 – 20 mA 1.1 Montage des Moduls Gehäuse des Anzeigegerätes öffnen RS 232-Buchse tauschen Befestigungsschrauben (6x) an der Hauptplatine des Anzeigegerätes entfernen 2 Schrauben mit Muttern und Abstandshalter an der Hauptplatine anbringen und Hauptplatine wieder am Gehäuse befestigen...
  • Page 5 Eingebaute RS 232-Buchse mit den entsprechenden Anschlüssen der Platine verbinden Anzeigegerät an Stromversorgung anschließen Zusätzliche Stromversorgung an Analog-Modul anschließen KFB-A04-A05-IA-d-1910...
  • Page 6: Prüfen Der Anschlüsse

    0 V anzeigen; zur Korrektur VR 1 nachstellen 1.2.2 Mit Max-Last: Wägeplatte mit Max-Last belasten ̴ Meßwert sollte 10 V anzeigen; zur Korrektur VR 1 nachstellen ̴ Wägeplatte entlasten; Meßwert sollte 0 V betragen; das Analog-Modul ist somit korrekt angeschlossen KFB-A04-A05-IA-d-1910...
  • Page 8 KERN KFB-A04-A05 Version 1.0 2019-02 Installation Instructions Analogue module Contents General hints ....................3 Installing the module ......................3 Check the connections ......................5 1.2.1 With no load: .......................... 5 1.2.2 With maximum load: ....................... 5 KFB-A04-A05-IA-e-1910...
  • Page 9: General Hints

    Can be connected to the following KERN models: • KFB-TAM • UFB • UFA • IFB • NFB • BFB KFB-A04 KFB-A05 0 – 10 V 4 - 20 mA 1.1 Installing the module Open the display device’s housing Exchange RS 232 bushing Remove the fastening screws (6x) from the display device’s main board...
  • Page 10 Connect the built-in RS 232 bushing to the relevant sockets on the board Connect the display device to the power supply Connect the additional power supply to the analogue module KFB-A04-A05-IA-e-1910...
  • Page 11: Check The Connections

    Load weighing plate with maximum load The reading value should show ~ 10 V; readjust VR 1 to correct Remove the load from the weighing plate; the reading value should be ~ 0 V; this means that the analogue module has been connected correctly KFB-A04-A05-IA-e-1910...
  • Page 12 KERN KFB-A04-A05 Version 1.0 2019-02 Notice d'installation Modules analogiques Table des matières Généralités ....................3 Montage des modules ......................3 Contrôle des raccordements ....................5 1.2.1 Sans charge: .......................... 5 1.2.2 Avec charge max.: ......................... 5 KFB-A04-A05-IA-f-1910...
  • Page 13: Généralités

    Connexion possible aux modules KERN suivants : • KFB-TAM • UFB • UFA • IFB • NFB • BFB KFB-A04 KFB-A05 0 – 10 V 4 - 20 mA 1.1 Montage des modules Ouvrir le boîtier de l’appareil d‘affichage Remplacement au connecteur RS 232 Enlever les vis de fixation (6x) sur la platine principale de l’appareil d’affichage...
  • Page 14 Relier la douille RS 232 avec les raccords correspondants à la platine Raccorder l’appareil d’affichage à l’alimentation électrique Raccorder l’alimentation électrique supplémentaire au module analogique KFB-A04-A05-IA-f-1910...
  • Page 15: Contrôle Des Raccordements

    Charger la plaque de pesage avec la charge max. La valeur de mesure doit afficher ~ 10 V; Régler à nouveau VR 1 pour correction Décharger la plaque de pesage ; la valeur de mesure devrait être ~ 0 V; le module analogique est connecté ainsi correctement KFB-A04-A05-IA-f-1910...

Ce manuel est également adapté pour:

Kfb-a05

Table des Matières