Step 4: Adjust the air inlet direction
(From rear side to under-side.)
1. Take off the ventilation panel and flange.
Ventilation panel
2. Change the mounting positions of the
ventilation panel and air return flange.
Air return flange
3. When installing the filter mesh, fit it into the
flange as illustrated in the following figure.
NOTE: All the figures in this manual are for
demonstration purposes only. The air conditioner
you have purchased may be slightly different in
design, though similar in shape.
Step 5: Fresh air duct installation
Dimension:
Air return flange
Fig. 4.11
Ventilation panel
Fig. 4.12
Pump maintainance:
Fig. 4.13
1. Remove four screws from the drain pump.
2. Unplug the pump power supply and water
3. Detach the pump.
12
Duct joint for fresh air
MODLE
18-60
Ø
.
Step 6: Motor and drain pump maintenance
(the rear ventilated panel is used as an example)

Motor maintenance:

1. Take off the ventilated panel.
2. Take off the blower housing.
3. Take off the motor.
level switch cable.
Ø160mm .
Fig. 4.14
Mofor
Blower housing
Ventilated panel
Fig. 4.15
Pump
Fig. 4.16