Lippert Components Duraself Flow Max Manuel D'installation Et D'utilisation
Lippert Components Duraself Flow Max Manuel D'installation Et D'utilisation

Lippert Components Duraself Flow Max Manuel D'installation Et D'utilisation

Pompe à fluide de 12 vcc

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Table of Contents
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lippertcomponents.com
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
574-537-8900
Flow Max
Fluid Pump
Installation and Owner's Manual
(For Aftermarket Application)
Flow Max
DC Fluid Pump
by Duraself
Installation and
Owner's Manual
(For Aftermarket Applications)
2
2
3
3
3
3
4
5
5
6
7
1
Rev: 11.17 - Flow Max
12V DC
by Duraself
12V
12V DC Fluid Pump

Publicité

Table des Matières
loading

Sommaire des Matières pour Lippert Components Duraself Flow Max

  • Page 1: Table Des Matières

    Flow Max 12V DC ™ Fluid Pump by Duraself Installation and Owner’s Manual (For Aftermarket Application) Flow Max ™ DC Fluid Pump by Duraself Installation and Owner’s Manual (For Aftermarket Applications) Table of Contents Introduction ..........Parts List .
  • Page 2: Introduction

    Flow Max 12V DC ™ Fluid Pump by Duraself Installation and Owner’s Manual (For Aftermarket Application) Introduction Parts List The Flow Max Fluid Pump by Duraself (Model Number: ™ DS-01233-D) delivers smooth, consistent flows at all ranges of operation while drawing low current. The motor design incorporates ball bearings for long life and the motor is equipped with an integral thermal breaker.
  • Page 3: Resources Required

    Flow Max 12V DC ™ Fluid Pump by Duraself Installation and Owner’s Manual (For Aftermarket Application) Resources Required Mounting Instructions 1. Pump may be located at the same level or below the • Cordless or Electric Drill or Screw Gun water tank.
  • Page 4: Plumbing The System

    Flow Max 12V DC ™ Fluid Pump by Duraself Installation and Owner’s Manual (For Aftermarket Application) Plumbing The System NOTE: Hex/swivel barb fittings provide easy removal, if maintenance or access is required. The fittings are 1. Install in-line screen (Fig.2A) on the inlet side of the designed with a “taper seal”...
  • Page 5: Electrical Connections

    Flow Max 12V DC ™ Fluid Pump by Duraself Installation and Owner’s Manual (For Aftermarket Application) Sanitizing Electrical Connections Potable water systems require maintenance to keep components working properly to deliver a consistent flow of IF THE WIRE IS TOO SMALL, LOW VOLTAGE WILL fresh water.
  • Page 6: Winterizing

    Flow Max 12V DC ™ Fluid Pump by Duraself Installation and Owner’s Manual (For Aftermarket Application) Winterizing If water is allowed to freeze in the system, damage to the plumbing and pump may occur. To protect against damage from freezing, completely drain the tank, pump and plumbing and perform winterizing tasks.
  • Page 7: Troubleshooting Chart

    Flow Max 12V DC ™ Fluid Pump by Duraself Installation and Owner’s Manual (For Aftermarket Application) Troubleshooting chart Vibration caused by driving, sea conditions or transporting can loosen plumbing, strainers and pump hardware. Check for loose system components. Many symptoms can be resolved by tightening hardware. Refer to the chart for troubleshooting tips.
  • Page 8 (For Aftermarket Application) Notes Manual information may be distributed as a complete document only, unless Lippert Components provides explicit consent to distribute individual parts. All manual information is subject to change without notice. Revised editions will be available for free download at www.lippertcomponents.com.
  • Page 9 Flow Max 12V DC ™ Fluid Pump by Duraself Installation and Owner’s Manual (For Aftermarket Application) Pompe à fluide de ™ 12 VCC Flow Max par Duraself Manuel d’installation et d’utilisation (pour les applications du marché secondaire) Table des matières Introduction .
  • Page 10: Introduction

    Pompe à fluide de 12 VCC Flow Max ™ par Duraself Manuel d’installation et d’utilisation (pour les applications du marché secondaire) Introduction Liste de pièces La pompe à fluide Flow Max de Duraself (numéro de ™ modèle : DS-01233-D) assure un débit régulier et constant à...
  • Page 11: Outils Requis

    Pompe à fluide de 12 VCC Flow Max ™ par Duraself Manuel d’installation et d’utilisation (pour les applications du marché secondaire) Outils requis Instructions de montage 1. Installer la pompe au même niveau que le réservoir • Perceuse ou tournevis électrique ou sans fil d’eau ou sous le réservoir d’eau.
  • Page 12: Plomberie Du Système

    Pompe à fluide de 12 VCC Flow Max ™ par Duraself Manuel d’installation et d’utilisation (pour les applications du marché secondaire) Plomberie du système 3. Utiliser des tuyaux/tubes flexibles renforcés ayant un diamètre intérieur minimum de ½ po pour les conduites 1.
  • Page 13: Connexions Électriques

    Pompe à fluide de 12 VCC Flow Max ™ par Duraself Manuel d’installation et d’utilisation (pour les applications du marché secondaire) Assainissement Connexions électriques Les systèmes d’eau potable requièrent un entretien pour le bon fonctionnement des composants afin d’assurer SI LE FIL EST TROP PETIT, LA BASSE TENSION un débit constant d’eau fraîche.
  • Page 14: Hivernisation

    Pompe à fluide de 12 VCC Flow Max ™ par Duraself Manuel d’installation et d’utilisation (pour les applications du marché secondaire) Hivernisation Tableau de dépannage Les vibrations causées par la conduite, les conditions La plomberie et la pompe peuvent subir des dommages si nautiques ou le transport peuvent desserrer la plomberie, l’eau gèle dans le système.
  • Page 15 Pompe à fluide de 12 VCC Flow Max ™ par Duraself Manuel d’installation et d’utilisation (pour les applications du marché secondaire) Problèmes Quoi faire Vérifier les connexions électriques, les fusibles, le disjoncteur, l’interrupteur principal et la connexion de mise à la terre. La pompe Le moteur est-il chaud? Le sectionneur thermique a possiblement été...
  • Page 16 L’information contenue dans le présent manuel peut seulement être distribuée comme document complet, à moins d’obtenir au préalable un consentement explicite de la part de Lippert Components pour distribuer des parties individuelles. Tous les renseignements contenus dans le présent manuel peuvent être modifiés sans préavis. Les versions révisées pourront être téléchargées gratuitement à...

Table des Matières