L O w A i r L O S S M At t r e S S r e p L A C e M e n t S y S t e M

.0 SyMBOLS reFerenCe

Attention! Please read
accompanying documents
Double Insulated (Class II)
Functional Ground
Type BF Equipment
Do not immerse power con-
trol unit in liquid or spray
liquids directly on power
control unit
Declaration of Conformity to
Medical Device Directive
Underwriters Laboratory
Agency Approval (United
States/Canada)
International Electronics
Approval

indications:

This device is indicated to assist in the
treatment and/or prevention of pressure
ulcers as part of a holistic program of
pressure ulcer management. Always con-
sult a physician before using this device.

Contraindications:

Certain patient conditions (e.g. unstable
cervical fracture) are contraindicated for
use with this device. Patients who require
other adjuvant therapies (e.g. rotational
therapy) should not use this device. Al-
ways consult the patient's physician prior
to use.

.0 SAFety preCAutiOnS

installation:

Verify mattress anchor straps are attached
to bed frame securely. Test all bed frame
functions to verify no interference. Do
not place anything on the power unit.
Route power cord underneath bed frame
and verify freedom from hazard. See Sec-
tion 8.0 of this Manual ("Installation") for
further installation instructions.

Bed Linens:

This device incorporates a waterproof
cover that is moisture vapor permeable;
therefore it is recommended to limit bed
linens to one cotton sheet in order to max-
imize the system's performance. NOTE:
Only "breathable" incontinent pads are
recommended for use with this device.

Open Flames:

Do not expose this device to open flames,
lighters, or cigarettes. This device draws
room air continuously, therefore cigarette
smoking is not recommended near this
device. Cigarette smoke may damage in-
ternal components. Cigarettes may ignite
cotton bed linens. CAUTION: DO NOT
SMOKE CIGARETTES, PIPES, CIGARS,
OR ANY OTHER RELATED PROD-
UCTS ON OR AROUND THIS SYSTEM.
FLAMMABILITY HAZARD EXISTS.

Cross Contamination:

This device should be decontaminated
between patient installations. Refer to
section 14.0 of this Manual ("Cleaning
Instructions") for proper instructions.
Failure to disinfect may result in cross
contamination.

Bed Frame Consideration:

Verify that the patient weight, therapeu-
tic support surface, bed rails, etc. do not
exceed weight capacity of bed frame.
Verify patient weight does not exceed
this device's weight capacity.