Gentilin C 660/100 Manuel D'instructions page 42

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 69
Instruction manual Compressor Mod. C660/100 - E480/100 - E660/100
Rev. 01 - 07/2014 -
FREQUENCY
ONCE A DAY
Safety devices.
Electrical cable and plug.
Tank.
EVERY WEEk
Wheels.
n. 4 air filters.
2
3
1
2
C660
20
STANDARD mAINTENANCE TABLE
INTERVENTION AREA
INTERVENTION TYPE
Ensure they are intact, correctly installed and functioning.
Visual check of usage status.
Upon termination of each work cycle, rest the appliance on
the ground and drain the tank condensate pump opening the
condensate pump (A).
Wheel pressure check. Subsequently pump up with compressed
air up to a maximum of 2.5 bar.
Unscrew the screws (1).
Remove the cover (2).
Extract the filter (3) and clean it using compressed air.
Reassemble the filters and properly reposition the lid.
notE: REPlaCE in tHE inStanCE WHERE it iS WoRn.
A
2
3
1
2
E480 - E660

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

E 480/100E 660/100