5. START-UP
FIRST CLEANNING
Clean the unit before connecting to the electricity supply.
INSPECTION
Check that the voltage and power line frequency coincide with those indicated on the specification plate of the appliance.
The unit should not be used in threatening atmospheric or fire risk conditions.
Check that there are no defects on the unit resulting from its transportation. The manufacturer will not be liable for damage
suffered during transportation or arising from incorrect storage.
Check the operation of the moving components of the unit.
Check the safety of the control board, electrical cables and connections.
Check that all the interior and additional accessories are present.
GENERAL CONNECTIONS
Be sure the power cable is not damaged.
If the power cable is damaged it must be replaced by another type H05-VV-F or H05-VVH2-F. This repair must be
performed by qualified personnel.
It is essential that the electrical installation to which the unit is going to be connected has an EARTH LEAD, as well as the
necessary thermal and differential magnetic protection.
The power supply must have the suitable section for the consumption of the appliance.
If various units are installed in a row, each one must be connected independently to the power supply, avoiding the use of
extension leads or multiple plugs.
The manufacture disclaims all liability in the event that any of the above points are not followed.
OPERATING ELEMENTS AND INDICATORS
THERMOSTAT DIGITAL
TEMPERATURE DISPLAY
Once the inside of the unit is clean, connect the power supply and place the switch in the ON position. The thermostat display
shows the air temperature inside the unit.
• Three minutes after turning on the switch, the LED showing the compressor is working will light up permanently.
• The initial temperature that is shown on the thermostat display will be the amient temperature. As the machine works, the
temperature will reduce until it reaches its operating temperature..
OPERATIONS
HOW TO SEE THE SET
POINT
Push
for 6 or 7 sec until appear
Push
2 or 3 sec and it will appear the set
point. Release the key.
LED
To switch the instrument ON/OFF
DESCRIPTION
ON
FUNCTION
To display target set point
To display target set point
Light ONF/OFF
CompresSor ON/OFF
Fan ON/OFF