Display Messages - Schumacher Electric 715005061 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MAINTAINING A BATTERY
The 715005061 maintains both 6 and 12 volt batteries, keeping them at full charge.
It can charge small batteries and maintain both small and large batteries. If you are
maintaining a fully charged large battery, you are properly utilizing the battery charger.
However, if you use this battery charger to charge a large battery, such as a marine
deep-cycle battery that was not fully charged, you may not get the battery's full capacity.
Therefore, we do not recommend charging a large battery with this unit.
NOTE: The maintain mode technology allows you to safely charge and maintain a
healthy battery for extended periods of time. However, problems with the battery,
electrical problems in the vehicle, improper connections or other unanticipated
conditions could cause excessive current draws. As such, occasionally monitoring
your battery and the charging process is required.
DESULFATION MODE
If the battery is left discharged for an extended period of time, it could become sulfated
and not accept a normal charge. If the charger detects a sulfated battery, the charger
will switch to a special mode of operation designed for such batteries. If successful,
normal charging will resume after the battery is desulfated. Desulfation could take up
to 8 hours. If desulfation fails, charging will abort, the GREEN LED will flash, and the
display will show CHARGE ABORTED-BAD BATTERY.
ABORTED CHARGE
If charging cannot be completed normally, charging will abort. When charging aborts,
the charger's output is shut off, the GREEN LED will flash, and the display will show
CHARGE ABORTED-BAD BATTERY. To reset after an aborted charge, unplug the
charger from the outlet, wait a few moments and plug it back in.

13. DISPLAY MESSAGES

CONNECT CLAMPS (No LED lit) – Plugged into the AC outlet without the clamps
connected to a battery.
WARNING CLAMPS REVERSED (No LED lit) – Plugged into the AC outlet and
the clamps are connected backwards to a 6V or 12V battery.
ANALYZING BATTERY (Green LED lit) – Plugged into the AC outlet, and when
first connected to a 6V or 12V battery correctly.
CHARGING 12V – XX% (Green LED lit) – Plugged into the AC outlet and
correctly connected to a discharged 12V battery.
CHARGING 6V – XX% (Green LED lit) – Plugged into the AC outlet and correctly
connected to a discharged 6V battery.
FULLY CHARGED AUTO MAINTAINING (Green LED pulsing) – Plugged into the AC
outlet and correctly connected to a fully charged 6V or 12V battery.
• 12 •
487802781

Publicité

Table des Matières
loading